GUIDELINES FOR EXTENSION CORDS

Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy 
enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting 
in loss of power and overheating. The table below shows the correct size to be used according to cord length and 
nameplate ampere rating. When in doubt, use a heavier cord. The smaller the gauge number, the heavier the cord. 

Make sure your extension cord is properly wired and in good condition. Always replace a damaged extension cord 
or have it repaired by a qualified person before using it. 

Protect your extension cords from sharp objects, excessive heat and damp/wet areas. 

Use a separate electrical circuit for your tools. This circuit must not be less than a #12 wire and should be protected 
with a 15 A time-delayed fuse. Before connecting the motor to the power line, make sure the switch is in the OFF 
position and the electric current is rated the same as the current stamped on the motor nameplate. Running at a 
lower voltage will damage the motor. 

WARNING: 

This tool must be grounded while in use to protect the operator from electric shock. 

AMPERAGE

REQUIRED GAUGE FOR EXTENSION CORDS (UL Recommendations)

25 ft.

50 ft.

100 ft.

150 ft.

13A

12 gauge

10 gauge

8 gauge

6 gauge

ELECTRICAL INFORMATION

WARNING: 

This tool is for indoor use only. Do not expose to rain or use in damp locations.

GROUNDING INSTRUCTIONS

IN THE EVENT OF A MALFUNCTION OR BREAKDOWN, grounding provides the path of least resistance 
for an electric current and reduces the risk of electric shock. This tool is equipped with an electric cord that has an 
equipment grounding conductor and a grounding plug. The plug MUST be plugged into a matching outlet that is 
properly installed and grounded in accordance with ALL local codes and ordinances. 

DO NOT MODIFY THE PLUG PROVIDED. If it will not fit the outlet, have the proper outlet installed by a 
licensed electrician. 

IMPROPER CONNECTION of the equipment grounding conductor can result in electric shock. The conduc-
tor with the green insulation (with or without yellow stripes) is the equipment grounding conductor. If repair or 
replacement of the electric cord or plug is necessary, DO NOT connect the equipment grounding conductor to a 
live terminal. 

CHECK with a licensed electrician or service personnel if you do not completely understand the grounding instruc-
tions or whether the tool is properly grounded. 

CAUTION: In all cases, make certain the outlet in question is properly grounded. If you are not sure, have a li-
censed electrician check the outlet. 

6

Summary of Contents for 2287

Page 1: ...ged trouble free performance Pay close attention to the rules for safe operation warnings and cautions If you use your tool properly and for intended purpose you will enjoy years of safe reliable service IMPORTANT NEED HELP CONTACT US Have product questions Need technical support Please feel free to contact us at 800 232 1195 techsupport wenproducts com WENPRODUCTS COM M F 8AM 5PM CST 4000049 For ...

Page 2: ...0 Hz 3 Wire 6 Gallon 125 PSI 95 PSIG 125 PSIG Quick Coupler 1 4 NPT 3 2 CFM at 90 PSI 4 2 CFM at 40 PSI 50 Single Stage 23 6 x 13 8 x 22 8 inches 57 3 pounds 2 TABLE OF CONTENTS Technical Data 2 3 4 6 7 8 8 10 11 12 14 General Safety Rules Specific Safety Rules for Compressors Know Your Compressor Operation Assembly Troubleshooting Warranty Parts List Exploded View Maintenance Electrical Informati...

Page 3: ...ying alert and knowing how your item works SAVE THESE SAFETY INSTRUCTIONS WARNING Read all safety warnings and all instructions Failure to follow the warnings and instruc tions may result in electric shock fire and serious injury To avoid mistakes and serious injury do not plug in your tool until the following steps have been read and understood WORK AREA SAFETY 1 Keep work area clean and well lit...

Page 4: ...s Check for misalignment of moving parts jamming breakage improper mounting or any other conditions that may affect the tool s operation Do not use the power tool if the switch does not turn ON OFF Any part that is damaged should be properly repaired or replaced before use 3 Do not force the tool to do a job for which it was not designed Use the correct power tool and accessories and follow the in...

Page 5: ...ile plugged in Unplug compressor and detach hoses and accessories after use 12 Drain tank daily or after use Internal rust causes tank failures and explosions 13 Do not use the air hose to move your air compressor 14 Do not grind puncture torch or in anyway modify the compressor s tank 15 Disconnect the plug from the power source and drain all air from the tank before making any adjustments changi...

Page 6: ...RED GAUGE FOR EXTENSION CORDS UL Recommendations 25 ft 50 ft 100 ft 150 ft 13A 12 gauge 10 gauge 8 gauge 6 gauge ELECTRICAL INFORMATION WARNING This tool is for indoor use only Do not expose to rain or use in damp locations GROUNDING INSTRUCTIONS IN THE EVENT OF A MALFUNCTION OR BREAKDOWN grounding provides the path of least resistance for an electric current and reduces the risk of electric shock...

Page 7: ...UR AIR COMPRESSOR Tank Tank Drain Valve Motor Handle Power Cord Pressure Switch Regulated Pressure Gauge Air Filter Air Pressure Regulator Air Line Outlet Oil Cap Breather Pump Oil Gauge Tank Pressure Gauge 7 ...

Page 8: ...e compressor to automatically start up and shut down depending on its need for air NOTE make sure this switch is set to OFF before unplugging plug ging in or storing the compressor INSTALLING THE WHEELS Insert bolt M10X1 25X57 into the wheel through the wheel bracket and 10mm flat washer then tighten with M10X1 25 hex nut Repeat for both wheels INSTALLING THE AIR FILTER Remove the plastic plug Ins...

Page 9: ...ure that this pressure is not higher than the working pressure of any pneumatic tools hooked up to the compressor Using a pressure higher than the rated pressure of an attached tool creates the possibility of damaging or in worse case scenarios bursting said power tool Using a pressure that is too low for a tool can result in misfires and improper functionality 3 2 1 5 4 SHUTTING DOWN THE COMPRESS...

Page 10: ...When the oil level is below B refill with semi synthetic compressor oil until the level reaches the center of the red circle in the oil gauge Oil should be changed after 200 hours of operation Prepare a container to catch the oil and unscrew the M6 oil drain plug on the pump head The compressor may need to be tipped slightly to let the oil drain completely After the oil has been drained tighten th...

Page 11: ...sor is too small Check the requirements of the pneumatic tool Make sure the specifications of this compressor meet the requirements Motor won t run 1 Tank pressure is too high 2 Thermal overload protection on the motor has been tripped 3 Power source isn t working 4 Check valve part 11 is stuck open 1 Motor will start automatically once the tank pressure drops 2 Let the motor cool down for a few m...

Page 12: ...12 EXPLODED VIEW AND PARTS LIST ...

Page 13: ...15 2202 016 Elbow 3 8 NPT 9 16 1 16 2289 017 Ferrule 3 8 Tubing 2 17 2289 018 Ferrule 1 4 Tubing 2 18 2289 019 Nut Compression 3 8 9 16UNEF 2 19 2289 020 Nut Compression 1 4 7 16UNS 2 20 2287 020 Cooling Fin 3 8 450 1 21 2287 021 Outlet Tube 3 8 L224H 1 22 2287 022 Tube Pressure Relief L26 1 23 2287 023 Rubber Grip Handle 1 24 2202 028 Bolt M10X1 25X55 2 25 2287 025 Bolt Hex Head M8X1 25X25mm 1 26...

Page 14: ...The prod uct must be shipped in its original container or an equivalent properly packed to withstand the hazards of ship ment The product must be fully insured with a copy of the warranty card and or the proof of purchase enclosed There must also be a description of the problem in order to help our repairs department diagnose and fix the issue Repairs will be made and the product will be returned ...

Page 15: ......

Page 16: ...THANKS FOR REMEMBERING ...