Weltem Icen WPC-23000 Owner'S Manual Download Page 6

6

7

Owner’s Manual

WPC-23000

Operation

CONTROL PANEL

1. 

POWER BUTTON

: Activates unit when POWER BUTTON is pressed. If POWER BUTTON is 

                                     pressed during operation, unit stops.
2. 

BLOWER BUTTON

: Indicates fan speed. (Not available for 3 phase model)

3. 

COOL BUTTON

: Activates compressor and begins producing cool air in 5 seconds after 

     button is pressed.
4. 

TIMER BUTTON

: Enters to Timer Setting Mode by pressing TIMER BUTTON for 1 seconds. 

     Two digits on CURRENT TEMP indicate hour(s) and two digits on  TARGET TEMP indicate 
     minutes. Set desired off-time by pressing SET TEMP BUTTONS.
5. 

ALARM

: Alarm indicator lights (blinks) and indicates abnormal system operation. 

     If Alarm occurs, compressor stops. System operation stops when Alarm light is activated 
     (blinks) longer than 3 minutes.
6. 

SPOT/COOL

: Lights (blinks) when unit is operated on SPOT/COOL mode.

7. 

SET TEMP BUTTONS

:  Change target temperature/data value by +/-1. Press the SET TEMP 

     BUTTONS to set temperature. Upper button is to heighten temperature and Lower button 

     is to lower temperture.

8. 

TARGET TEMP

: Displays unit set temperature for ROOM/COOL mode only. 

     Set TARGET TEMP 0 

 or 32

℉ 

on SPOT/COOL mode.

108&3

#-08&3

$00-

5*.&3

4105$00-

"-"3.

$633&/5

5&.1)6.*%

5"3(&5

5&.1)6.*%

1

2

7

3

4

6

5

9

8

Figure 9

Summary of Contents for Icen WPC-23000

Page 1: ...Hz 83 000 13 800 9 2 21 Model No Nema Plug Power Cord Gauge AWG Power Cord Length m Dimensions W x D x H in mm WPC 23000 Terminal type 10 3 28 9 x 51 6 x 59 8 735 x 1 310 x 1 520 Model No Weight Net G...

Page 2: ...0 450 250 Model No Indoor Air Flow CFM CMM Wheels pcs diameter Hot Air Duct Di ameter In mm Maximum Exhaust Duct Lenght ft m WPC 23000 2550 73 4 127mm 20 500 100 30 Safety Devices Compressor overload...

Page 3: ...3 Owner s Manual WPC 23000...

Page 4: ...install the cord holder on the air condi oner as shown in Figure 4 TOP FAN EXHAUST FLANGE 1 Remove the top fan exhaust flange from carton 2 Place the top fan exhaust flange on the top of air condi on...

Page 5: ...5 Owner s Manual WPC 23000...

Page 6: ...ate minutes Set desired off time by pressing SET TEMP BUTTONS 5 ALARM Alarm indicator lights blinks and indicates abnormal system operation If Alarm occurs compressor stops System operation stops when...

Page 7: ...will blink 2 times and Figure will change to F ALARM codes blink and are displayed when abnormal operation occurs SPOT COOL mode ROOM COOL mode Enter to ROOM COOL mode if COOL BUTTON and TIMER BUTTON...

Page 8: ...guard Slide filter up and use a vacuum cleaner to remove the dust from the filter Remove dust from the filter using a vacuum cleaner hose a achment If required wash the filter in lukewarm water with a...

Page 9: ...9 Owner s Manual WPC 23000 Product Portable Air Conditioner Model No Date of Purchase Place of Purchase Serial No Period of Warranty...

Page 10: ...nkorblockage Improperaircircula on Highambient temperature Cleantheairfilter Ensureexhaustductisnot blockedorkinked Ambienttemperaturemust beunder45 C 113 F Ambienttemperatureis toohigh Unstablevoltag...

Page 11: ...OM CP N 1 L 1 COM CO Power Remote Control Option EXT COM FUSE FUSE HIGH PRESSURE SWITCH PHASE PROTECTOR C CM B NC A NO R L1 S L2 T L3 TR 220V R T 380 460V R S T R S T R S T S MC 2 OCR 2 R S T R T S S...

Page 12: ...flows from the cold air outlet 1 Ambient air cannot be properly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on...

Page 13: ...13 Owner s Manual WPC 23000...

Page 14: ...14 Owner s Manual WPC 23000...

Page 15: ...15 Owner s Manual WPC 23000...

Page 16: ...16 Owner s Manual WPC 23000 Manufactured in Weltem co Ltd 154 Jayumuyeok 3 gil Masanhoewon gu Changwon City Gyeongsangnam do 51340 Korea www weltem com Printed in December 2019...