INSTALLATION (continued)
7
361
301
669
OpM
anual
for
W
F
A
E
-30
F
Ele
c
tric Fr
yer
ELECTRICAL INSTALLATION
Refer to the nameplate on the front of the fryer and to the specifications
listed on page 1 of this manual. Verify that electric service voltage,
phase and amperage capacity meet or exceed these specifications.
US and Canadian Units Only:
Field wiring must be no less than 12 ga. Solid copper wire, rated for at
lease 75ºC.
EU Units Only
:
•
Supply cords shall be oil-resistant, sheathed flexible cable
not lighter than ordinary polychloroprene or other equivalent
synthetic elastomer-sheathed cord (code designation 245 IEC 57)
or approved metal conduit connection.
•
Supply power wire must not wxceed 2 m between the point where
cord or cord guard enters the appliance and the entry to the plug.
•
Minimum cross-sectional area of conductors shall not be less
than 2.5 mm
2
.
Fryers are shipped from the factory wired for 3Ø. Verify that field wiring
conforms to the
Three-Phase Wiring Diagram
included with the fryer.
NOTE:
Fryers are FIELD-CONVERTIBLE TO 1Ø. For single-phase
operation refer to the
3-phase to 1-phase Instructions
included with the
fryer. Verify that both internal wiring and field wiring conforms to the
Single-Phase Wiring Diagram
included with the fryer.
NOTE:
Supplied strain relief is intended for use with metallic conduit.
For flexible power cords, electrical installer must supply an appropriate
approved strain relief fitting.
INSTRUCTIONS
1. Using a screwdriver, remove terminal block access panel located
behind front door marked “NOTICE - REMOVE THIS PANEL FOR
TERMINAL
BLOCK”.
2. Knock out the appropriate hole plug located on enclosure panel,
and connect conduit strain relief.
3. Thread supply leads through strain relief. Connect power leads to
terminals marked “L1”, “L2”, “L3”. On EU units, connect neutral
lead to terminal marked “N”.
4. Connect green-with-yellow-trace lead to ground lug marked .
5. Secure all connections and reinstall terminal access cover.
IMPORTANT:
Field wiring must be routed and secured away from the FRYPOT,
TUBING and FILTER PUMP MOTOR. Field wiring must be
configured to allow access to the rear of fryer for cleaning and
access to the filter pump motor RESET BUTTON.
6.
On EU units
: Equal potential grounding screw is located at rear of
frame assembly, marked .
Remove screw and secure an appropriate grounding wire with
terminal.
IMPORTANT:
Electric installation of this
appliance must be performed
by a licensed electrician.
Installation must conform to
the requirements of local
codes and ordinances, as
well as to the requirements of
the National Electrical Code.
IMPORTANT:
This installation instruction
has been prepared for
personnel authorized,
qualified, certified or licensed
to install electrical equipment,
who should perfprm the initial
start-up and adjustments
covered in this manual.
IMPORTANT:
Verify the incoming voltage
matches unit nameplat e
specifications. Wiring this
appliance to voltage other
than as specified can cause
severe damage to the
appliance, or will result in
degraded performance.
IMPORTANT (EU only):
An approved all-pole power
disconnect switch with at
least 3mm contact gap, must
be supplied and installed in
the fixed wiring in an
accessible location (close
proximity to the appliance)
by a licensed electrician.
Fig. 2 Field Wiring
G
FRYPOT
CONDUIT
FITTING
90º
FILTER
PUMP &
MOTOR
POWER
CORD