INSTALLATION
5
4.
For “top-mounted” warmers (i.e. warmers mounted from above
the
counter
top):
a. Verify that provided sealants are applied to the underside
of the warmer top flange prior to setting the unit into the
cutout.
b.
After
installation,
verify
that the tabs on the Wellsloks are
turned out to lock the warmer into the counter
c. Apply a thin bead of food-grade silicone sealant around the
flange to seal it to the counter.
d. Wellslok extension kits are available for installing warmers
in counter tops where the standard Wellslok would not
normally reach. The extension kit will adapt to counter
tops up to 1¾” thick.
ELECTRICAL INSTALLATION
1.
Refer to the product nameplate. Verify the electrical service
power. Voltage and phase must match the nameplate
specifications. Wiring the warmer to the wrong voltage can
severely damage the unit or cause noticeably decreased
performance.
2.
Available electrical service amperage must meet or exceed the
specifications listed on the specification sheet provided with the
warmer.
3.
Warmer and control unit must be connected to an appropriate
building ground. Ground connection will be marked “GND” or
” " .
NOTE:
Wire gauge, insulation type and temperature rating , as
well as type, size and construction of conduit, must meet or exceed
applicable specifications of local codes and of the National
Electrical
Code.
PLUMBING INSTALLATION
For use in the State of Massachusetts, this appliance must be
installed in compliance with
Massachusetts Fuel Gas and
Plumbing Code CMR 248.
1.
IMPORTANT:
All plumbing installations must be performed by
a
qualified
plumber.
2.
For units equipped with a DRAIN LINE: Some jurisdictions
may require an approved air gap or other back-flow
prevention device in the drain. It is the responsibility of the
plumber to determine such requirement, to provide and
properly install the required device.
NOTE:
Damage caused by
leaks due to improper
installation is NOT covered by
warranty.
CAUTION:
SHOCK HAZARD
The ground lug of this
appliance must be connected
to a suitable building ground.
IMPORTANT:
Contact a licensed electrician
to install and connect
electrical power to the
appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
IMPORTANT:
Electrical
installation other than as
specified on the specification
sheet will void the UL listing,
and may void the warranty.
NOTE:
Plumb connections
must be made in compliance
with all Federal, State and
Local Plumbing Codes and
Ordinances.
M
012C.03 2M
-308031
Owne
rs M
anual fo
r Three
-W
e
ll
In
f.Sw
. M
O
D
W
armer
s