background image

M01

1A.01  2M-308012  Owners Manual for Built-In Rectangular T’Stat W

armers

INSTALLATION

5

    4.  Top-Mounted Warmers

  

a.  Verify that provided sealants are applied to the underside of the 

warmer top flange prior to setting the unit into the cutout.

 

b.  After installation, verify that all supplied fasteners and other  

mounting hardware is properly installed and tightened.

 

c.  Apply a thin bead of food-grade silicone sealant around the  flange 

to seal it to the counter.

ELECTRICAL INSTALLATION

     1.  Refer to the product nameplate.  Verify the electrical service 

power.  Voltage and phase must match the nameplate 

specifications.  Wiring the warmer to the wrong voltage can 

severely damage the unit or cause noticeably decreased 

performance.  

     2.  Available electrical service amperage must meet or exceed the  

specifications listed on the specification sheet provided with the 

warmer.

     3.  Warmer and control unit must be connected to an appropriate 

building ground.  Ground connection will be marked “GND” or

 

”       “ .

NOTE:

  Wire gauge, insulation type and temperature rating , 

as well as type, size and construction of conduit, must meet 

or exceed  applicable specifications of local codes and of the 

National Electrical Code.

PLUMBING INSTALLATION

For use in the State of Massachusetts, this appliance must be installed 

in compliance with 

Massachusetts Fuel Gas and Plumbing Code 

CMR 248.

     1.  IMPORTANT:  All plumbing installations must be performed by  

a qualified plumber.

     2.  For units equipped with a DRAIN LINE:  Some jurisdictions  may 

require an approved air gap or other back-flow prevention device 

in the drain.  It is the responsibility of the plumber to determine 

such requirement, to provide and  properly install the required 

device. 

NOTE:  Damage caused 

by leaks due to improper 

installation is NOT covered by 

warranty. 

CAUTION:

SHOCK  HAZARD

The ground lug of this  

appliance must be connected 

to a suitable building ground.

IMPORTANT:

Contact a licensed electrician 

to install and connect electrical 

power to the appliance.

IMPORTANT:

Damage due to being
connected to the wrong     

voltage or phase is NOT    

covered by warranty.
IMPORTANT:  Electrical      

installation other than as 

specified on the specification 

sheet will void the UL  listing, 

and may void the warranty. 
NOTE:  Plumb connections 

must be made in compliance 

with all Federal, State and  

Local Plumbing Codes and 

Ordinances.

Summary of Contents for HMP-6

Page 1: ...sible for TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact...

Page 2: ...ult of normal use within the time period and limitations defined in this warranty will at Wells discretion have the parts replaced or repaired by Wells or a Wells authorized service agency THIS WARRAN...

Page 3: ...Wells Manufacturing appliance Proper installation professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long economical ser...

Page 4: ...pped with an INDICATOR LIGHT the light will glow when the thermostat is calling for heat i e the element is energized 4 The TEMPERATURE CONTROL KNOB will rotate approximately 300 and will reach a stop...

Page 5: ...ion No other use is recommended or authorized by the manufacturer or its agents Operators of this appliance must be familiar with the appliance use limitations and associated restrictions Operating in...

Page 6: ...rting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessor...

Page 7: ...nstruction of conduit must meet or exceed applicable specifications of local codes and of the National Electrical Code PLUMBING INSTALLATION For use in the State of Massachusetts this appliance must b...

Page 8: ...ed by warranty PRE HEATING THE WARMER 1 Place desired pan s or inset s with appropriate adapter top on warmer 2 Turn temperature control to highest temperature setting 3 Allow warmer to preheat for ap...

Page 9: ...el Warmer pans insets and other vessels are subject to a harsher environment Wells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stai...

Page 10: ...spect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causing a potential fir...

Page 11: ...or covers accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat cont...

Page 12: ...y flange to counter seal is sound or reseal with food grade silicone sealant Pan leaking or other internal damage Contact your Authorized Wells Service Agency for repairs Internal damage Contact your...

Page 13: ...352 ELEMENT PAN COVER P2 305642 CONTROL KNOB ASSEMBLY 2R 40498 PILOT LIGHT RETAINER CLIP 2C 63271 POP RIVET 2C 34284 STRAIGHT CONDUIT FITTING 2K 37748X ELEMENT CLIP 2C 30397 HEATING ELEMENT 2N 45431UL...

Page 14: ...E THERMOSTAT 2T 38968 CONTROL KNOB ASSEMBLY 2R 40498 THERMOSTAT PLATE P2 41461 ELEMENT COVER P2 41462 PAN ASSEMBLY P2 41463 HEATING ELEMENT 2N 45431UL DRAIN SCREEN ASSEMBLY 2V Z17446 PILOT LIGHT RETAI...

Page 15: ...B ASSEMBLY 2R 40498 POP RIVET 2C 34284 CONTROL PANEL I7 Z12221 K TYPE THERMOSTAT 2T 38968 6 use 2T 46551 90 DEGREE BEND CONDUIT FITTING 2K 34136X 6 use 2K 33996X HEATING ELEMENT 2N 45431UL ELEMENT COV...

Page 16: ...WIRING DIAGRAM 14 HMP 6 Series...

Page 17: ...M011A 01 2M 308012 Owners Manual for Built In Rectangular T Stat Warmers NOTES 15...

Page 18: ...NOTES 16...

Page 19: ...TION PART NO ACCESSORIES DRAIN VALVE EXTENSION KIT extension from drain to counter front with remote handle for use with D models only excluding DM models 5P 20385 DRAIN SCREEN P2 31869 OPTIONAL 72 WI...

Page 20: ...WELLS MANUFACTURING 265 Hobson Street Smithville Tennessee 37166 telephone 314 678 6314 fax 314 781 2714 www wells mfg com...

Reviews: