background image

M01
1B.03

 2M-308016

    Owners Manual for Unshrouded Drop-In Bottom Mounted W

armers w/T

-Stat Controls

 WIRING DIAGRAM

12

Summary of Contents for 276TDFI

Page 1: ...manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any questions concerning in...

Page 2: ...receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnotice...

Page 3: ...l operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to prope...

Page 4: ...t is energized 4 The TEMPERATURE CONTROL KNOB will rotate approximately 300 and will reach a stop at both ends The OFF position is marked NOTE The dial position is an indication of the temperature set...

Page 5: ...man consumption No other use is recommended or authorized by the manufacturer or its agents Operators of this appliance must be familiar with the appliance use limitations and associated restrictions...

Page 6: ...nd understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a convenient place for...

Page 7: ...round Ground connection will be marked GND or NOTE Wire gauge insulation type and temperature rating as well as type size and construction of conduit must meet or exceed applicable specifications of l...

Page 8: ...ARMER 1 Place desired pan s or inset s with appropriate adapter top on warmer a Insets are available as accessories in 2 qt 4qt 7 qt and 11 qt sizes with lids and adapter tops b For dry operation a 6...

Page 9: ...tainless steel Warmer pans insets and other vessels are subject to a harsher environment Wells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest...

Page 10: ...to neutralize all detergent cleanser residue 4 Inspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insul...

Page 11: ...l 1 1 1 2 deep or covers accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner...

Page 12: ...t your Authorized Wells Service Agency for repairs Warmer slow to heat Mineral deposits on pan acting as a insulator Clean pan s with delime cleaner Wired to wrong voltage Verify supply voltage must m...

Page 13: ...M011B 03 2M 308016 Owners Manual for Unshrouded Drop In Bottom Mounted Warmers w T Stat Controls WIRING DIAGRAM 11...

Page 14: ...M011B 03 2M 308016 Owners Manual for Unshrouded Drop In Bottom Mounted Warmers w T Stat Controls WIRING DIAGRAM 12...

Page 15: ...M011B 03 2M 308016 Owners Manual for Unshrouded Drop In Bottom Mounted Warmers w T Stat Controls 13 NOTES...

Page 16: ...308016 Owners Manual for Unshrouded Drop In Bottom Mounted Warmers w T Stat Controls EXPLODED VIEW PARTS LIST 14 MODELS SS206T D SS206ET D IL1972b PL011B 4 25 12 2 Top Mount Bottom Mount 3 4 12 11 10...

Page 17: ...sy SS206T 208 240V P2 WL0089 Pan Elem Assy SS206TU 208 230 240 SS206ET 230 SS206ETD 230 SS206TD 230 SS206TDU SS206TDU6 SS206TU SS206TU6 SS206ULTDBM P2 WL0445 PAN EL ASM 208 240 1650W SS206TD6HI N1 307...

Page 18: ...SS276ULT D 2T 38968 96 CAP 2T 46551 THERMOSTAT MOUNTING BRACKET P2 40843 CONTROL PANEL I7 Z12221 CONTROL KNOB 2R 40498 CONTROL BOX P2 306959 FITITNG FLEX CONDUIT 2K 34136X WASHER FIbER 2I Z12311 CONDU...

Page 19: ...0498 PILOT LIGHT not illustrated 2J 35687 276TDFI 120V SS276T 230V 2J 31157 SS276T 120V CONTROL BOX SS276T 120 208 240V P2 Z16805 SS276T 230V P2 306085 CONDUIT FLEX 1 2 x 28 P2 40634 3 8 X 28 P2 45183...

Page 20: ...M011B 03 2M 308016 Owners Manual for Unshrouded Drop In Bottom Mounted Warmers w T Stat Controls NOTES 18...

Page 21: ...M011B 03 2M 308016 Owners Manual for Unshrouded Drop In Bottom Mounted Warmers w T Stat Controls NOTES 19...

Page 22: ...of TMPT to hold one 11 qt and one 7 qt inset WS 21621 ADAPTER TOP convert 12 x 20 warmer to hold two 7 qt insets WS 21502 ADAPTER TOP convert 12 x 20 warmer to hold two 4 qt and two 2 qt DD 21503 ADAP...

Page 23: ...dapt to wood counter up to 1 thick WS 22593 Wellslok Extension Kits for UL Listed units approved for installation in wood counter tops One well units require one kit Two and three well units require t...

Page 24: ...WELLS MANUFACTURING 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wellsbloomfield com...