17
②
. The default steam temperature is 45
℃
and the default duration is 45min.
③
Setting of steam bath temperature: After turning on the steam machine, move the cursor
to , press the shuttle switch or press on remote control to enter the
temperature setting mode. As the icon
℃
flashes, rotate the shuttle switch to adjust the
temperature or press on the remote control to raise the temperature or
to lower
the temperature. Temperature setting range: 25 ~ 60
℃
.
④
setting of duration: After turning on the steam machine, move the cursor to ,
press the shuttle switch or press on remote control to enter the temperature
setting mode, then press once again to enter duration setting mode. As the icon
flashes, rotate the shuttle switch to adjust the time or press on the remote control
to increase the time or to decrease the time. Timing range: 5 ~ 50min.
⑤
. Settings of temperature and time will automatically take effect in 3 seconds, the system
will exit the temperature and time setting mode.
⑥
Drainage: 5 minutes after the shutdown of system, the steam tank will drain water for 3
minutes.
2. Spray
Move the cursor to and press the shuttle switch. The first press will turn on
upper spray; the second press--switch to middle spray; the third press--switch to lower spray;
the fourth press will start the automatic cycle of upper, middle and lower spray,
automatically switch in every 5 seconds. the fifth press will turn off the spray.
In the case that the remote control is used to control the spray, press on the
remote control. The first press will turn on upper spray; the second press--switch to middle
spray; the third press--switch to lower spray; the fourth press will start the automatic cycle of
upper, middle and lower spray; the fifth press will turn off the spray.
Summary of Contents for WG-U693T
Page 14: ...14 ...