background image

1

 

 

 

 

                           

Steam Room Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WG-U693T    L 

 

 

 

Model 

Size 

L

x

WxH mm 

Light 

Steam 

generator 

Fan 

Loudsp

eaker 

faucet  Top 

shower 

Hand 

shower 

WG-U693T 

1450x950x2230 

 

 

 

 

 

 

 

 

                                                                     
   

 

 

 

 

Summary of Contents for WG-U693T

Page 1: ...1 Steam Room Manual WG U693T L Model Size LxWxH mm Light Steam generator Fan Loudsp eaker faucet Top shower Hand shower WG U693T 1450x950x2230 ...

Page 2: ... Ceiling light 8 Tray 14 Door handle 3 Computer panel 9 Top shower 15 Shower hose 4 Thermo mixer faucet 10 Shampoo shelf 16 Foot massage 5 Back jet 11 Shower pole 17 Hose of foot massage 6 Steam outlet 12 Hand shower 2 3 4 5 6 7 8 10 11 12 13 14 17 1 9 15 16 ...

Page 3: ...ter until feel comfortable 9 When using steam function please don t use the shower or water massage function 10 Keep your body away from the outlet of steam to avoid scald 11 Never start the motor without water if steam room with massage bathtub 12 Close the door and do not enter the steam shower when the sterilization is on 13 Keep any flammable material or any object with the temperature of over...

Page 4: ...arts Insert the wiring cords firmly and keep them away from any water pipe connector that may have water drips due to leakage Identify the connection symbols on the wiring cards before insertion as the error connection may damage the electrical parts in the steam room 2 Reliably connect the earth wire of the steam room to the indoor electrical grounding unit and make sure that it really works 3 Co...

Page 5: ...eeze bend or clog the flexible drain pipe to make sure of the fast and smooth drainage 3 In case of any leakage of the drainer stop it up with the rubber pad or silicone VI Installation steps A Two persons are required to assemble the unit B The glass is toughened safety glass Please take great care when handling and fitting the glass panels In particular avoid the glass edges coming into contact ...

Page 6: ...under the glass then put the glass into the track 4x16mm screw 4x20mm screw 4x20mm screw 4x25mm screw Put aluminium frame on the ground and set up as picture pay attention to protect the aluminium from scratch you can put a blanket or carton under the aluminium U shape seal ...

Page 7: ...7 3 Install the back wall glass 4x10mm screw 5 pcs please notice this glass is big and heavy Two persons lift the frame onto the tray ...

Page 8: ...8 4 To make the corner more fixed fasten by 4x10mm screw 2 pcs each side Install another back wall glass 4x10mm screw each side 5 pcs At the bottom fastern by 4x10mm screws ...

Page 9: ...l the wheel don t fasten the screw of wheel too tightly now Hang door glass into the track of aluminium adjust the wheel to fit well finally fasten the screw of wheel fasten another screw 4 16mm 4 pcs Put on the cover fasten screw and nut 4 pcs ...

Page 10: ...helf one person stand inside the steam another person stand behind the wall glass Fasten the screw from bottom Set up the base The back of shelf Install the rest accessories such as foot massage towel rail door handle etc ...

Page 11: ... glass seal outside 2 sides of fixed glass if the seal is too hard in winter you can drop this seal into hot water to make it soft You can use a wood to help installing the seal Glass in this side Install door side seal ...

Page 12: ...light to light loudspeaker to loudspeaker One wire of light doesn t connect fan Connect the hoses to C Check the symbols on A or B depending on your shower model on your thermo mixers front plate to find the correct position for the hoses on the back side of the mixer ...

Page 13: ...h of the plug works well in this way press RESET with the power indicator on If the red light is still on when TEST is pressed or is not on as RESET is pressed it means that the leakage protection malfunctions or has any trouble Please call the professional to make the repair at this time 3 All functions of the steam room can be used so long as its power supply and water supply are checked as norm...

Page 14: ...14 ...

Page 15: ...oaction of the panel Otherwise it will lead to malfunction or trigger the panel lock 2 all function keys are located at the most convenient locations 3 When the panel is on power it will give out one sound of ring B functions introduction 1 spare massage 2 steaming 3 exhaust fan 4 FM 5 lighting 6 ozone disinfection 7 bluetooth 8 telephone 1 start up shut down and unlocking of panel startup ...

Page 16: ...perable 2 Instruction for operation After stratup the default location of cursor will be Rotate the shuttle switch to move the cursor After the cursor moves to a function press the shuttle switch or the function keys on the remote control to quickly turn on and turn off the function The icons will light up after functions are turned on and vanish after functions are turned off 3 operating instruct...

Page 17: ...ncrease the time or to decrease the time Timing range 5 50min Settings of temperature and time will automatically take effect in 3 seconds the system will exit the temperature and time setting mode Drainage 5 minutes after the shutdown of system the steam tank will drain water for 3 minutes 2 Spray Move the cursor to and press the shuttle switch The first press will turn on upper spray the second ...

Page 18: ...te control to turn on or turn off the ozone After startup icon light up and all other functions will be disabled except lighting function Emission of ozone will last for 10 minutes then the exhaust fan will automatically start and operate for 15 minutes 6 Radio Function Move the cursor and press the shuttle switch or press on the remote control to turn on or turn off the radio function Icon will l...

Page 19: ...ash for two seconds in this way at most 10 radio frequencies can be stored on different channels Frequency range 87 5 108 0MHz Switch of channels When the radio is turned on and the panel is unlocked move the cursor to press the shuttle switch rotate the shuttle switch or press on the remote control to switch channels and play programs on the stored radio channel 7 Bluetooth Turn on the system and...

Page 20: ... of phone calls the cursor can only move between non multimedia functions and phone After the cursor moves to a non telephone icon it will automatically return to the phone icon for no operation in five seconds Multimedia control keys on the remote control will be disabled during ringing and reception of calls When a phone call comes in touch to reject the call 9 Volume control In the radio and Bl...

Page 21: ...de The fourth press would return to the steam temperature setting As the system enters the volume adjustment mode would begin to flash on the LCD screen Operation of thermo mixer faucet Four way functions thermo mixer Foot massage Hand shower Top shower Back jet Turn on off water And adjust water volume Adjust water temperature ...

Page 22: ...ral water valve is not open B Failure of inlet valve control system C Failure in water level detection After the steam function is turned on the system will open water inlet after it detects shortage of water If the system shows no water after 10 seconds or the tank remains unfilled after 1 minute the system would report E10 fault as well as turn off steam function and inlet valve E16 Temperature ...

Page 23: ...g tool 8 Ask the professional to remove the deposits in the steam generator after a certain times of thermal circulation 9 Drain off the remaining water in the steam generator each time after use to prolong its service life 10 Make a test to check the leakage protection performance of the leakage switch once a month the leakage switch is of proper performance as it trips when the test key on the l...

Reviews: