background image

Setting:

When switching on, hold the ”UP” key (3) until ON or

OFF appears in the display. 

The setting is saved when the "UP" button is released.
Repeat this step to change. 

Standard setback for control unit WAD 101IG

After placing the soldering iron on its stand, the nominal tem-
perature is reduced to 180°C and inert gas feed is shut off
after 2 min. The "AUTO-OFF" function is deactivated.

4. Equipotential bonding

The various circuit elements of the 3.5 mm jack bush make
4 variations possible:

Hard-grounded:

No plug (delivery form)

Equipotential bonding:

With plug, equalizer at center
contact (impedance 0 Ohms)

Potential free: 

With plug

Soft-grounded:

With plug and soldered 
resistance. Grounding via set 
resistance value.

5. Instructions for use

External input unit WCB 1 and WCB 2 (optional)

The following functions are possible when using an external
input unit.

Offset:

The real temperature of the soldering iron can be changed by
± 40°C by input of a temperature offset.

 

Setback:

Reduction of the required temperature set to 150°C / 300°F
(standby). The set-back time, the time after which the 
soldering station switches into standby mode, can be 
adjusted from 0-99 minutes. The set-back condition is 
indicated by a flashing actual value display. After a period
equal to three times the set-back time, „AUTO-OFF“ is 
activated. The soldering iron is switched off (flashing dash on
the display). The set-back or auto-off condition is ended by
pressing a button or finger switch pressure. During this 
process the required value set is briefly displayed.

Lock:

Locking the setpoint temperature. Settings cannot be 
changed after the soldering station has been locked.

°C/°F:

Switching the temperature display from °C to °F, and vice
versa.

Window:

Limitation of the temperature range to max. ± 99°C based on
a locked temperature resulting from the "LOCK” function. 
The locked temperature represents the median point of the
adjustable temperature range. 

Cal:

Re-adjustment of the soldering station (WCB 2 only).

PC interface:

RS232 (WCB 2 only).

Temp. gauge:

Integrated temperature gauge for thermal element Type K
(WCB 2 only).

Hot Air Soldering Tool

The hot air nozzles are screwed into the heater element. To
change the nozzle use the 8 SW socket spanner and lock the
heater element with an open ended spanner.

Important: 
The maximum thread depth is 5 mm (0.2"). 
A longer thread will irreparably damage the heater 
element.

Nitrogen N2 reduces oxidation and flux remains active for
longer. We recommend the nitrogen N2 that is available in
steel bottles. The bottle must be equipped with a 0-10 bar
pressure reducer.

Soldering Iron

The transition between the heater element/sensor and the
soldering iron bit must not be degraded by dirt, foreign bodies
or damage because these will have an effect on the 
precision of temperature regulation.

When heating up for the first time, wet the selectively tinna-
ble soldering iron bit with solder. This removes oxide layers
and soiling that have formed during storage. Always ensure
that the soldering iron bit is well tinned during breaks in sol-
dering and when placing in the holder. Do not use aggressi-
ve fluxes.

Important:
Always ensure that the soldering iron bit is correctly 
seated.

English      

19

Summary of Contents for WAD 101

Page 1: ...WAD 101 WAD 101IG 5 Commonwealth Ave Woburn MA 01801 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Page 2: ...Table of contents Page 1 Caution 17 2 Description Technical data 18 3 Commissioning 18 4 Equipotential bonding 19 5 Instruction for use 19 6 Accessories 20 7 Scope of supply 20...

Page 3: ...or Flow Rate 10 Power supply connector 11 Fuse 12 Quick Action Coupling for Compressed Air Connection 1 Mains switch 2 Digital display 3 Up Button 4 Down Button 5 Optical regulator 6 Equipotential bon...

Page 4: ...WAD 101 WAD 101IG WP 80IG WP 120IG...

Page 5: ...unit WAD 101 air flow is controlled by a finger switch integrated in the handle The air flow is controlled via a finger operated switch integrated in the handle The flow rate can be adjusted continuou...

Page 6: ...ched Setting the temperature The digital display 2 shows the actual value temperature By pressing the UP or DOWN key 3 4 the digital display 2 switches to the setpoint The setpoint can be changed by t...

Page 7: ...ired value set is briefly displayed Lock Locking the setpoint temperature Settings cannot be changed after the soldering station has been locked C F Switching the temperature display from C to F and v...

Page 8: ...soldering set with tool stand WSP 80IG PU WAD 101IG T005 29 198 99 Inert gas soldering iron WP 120IG PU WAD 101IG T005 15 161 99 WDH 10T stand with Stop Go function 7 Scope of supply WAD 101 Control...

Page 9: ...wo sides heated with hot plate D08 Hot air nozzle 15 0 mm 10 0 mm T005 87 277 81 two sides heated with hot plate D10 Hot air nozzle 18 0 mm 10 0 mm T005 87 277 84 two sides heated with hot plate 4 Sid...

Page 10: ...94 Circuit Diagram...

Page 11: ...Exploded Drawing 95...

Page 12: ...and registered Design of Apex Tool Group LLC 2015 Apex Tool Group LLC T005 56 806 09 01 2015 T005 56 806 08 11 2013 5 Commonwealth Ave Woburn MA 01801 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit...

Reviews: