Although the heat pump is electrically isolated from the rest of the unit, this only prevents
Important
—
the passage of electricity to or from the pool water. Grounding the unit is still required to protect
yourself from short circuits inside the unit. Make for adequate ground connection.
Check if the electrical mains voltage corresponds with the operating voltage of the heat pump prior to
hooking up the unit.
1.8
Warning:
5
- Do not place your hand or any other objects into the air outlet and fan. It could damage the heat
pump and cause injuries;
- In case of any abnormality with the heat pump, cut off the power immediately and contact a
professional technician;
- It is strongly advised to place a protective guard around the unit to keep children away from the heat
pump.
- An authorized electrician must connect the Heat Pump to the power. (230V 1ph or 400V 3ph)
230V / 1ph / 50Hz
380-400V / 3ph / 50Hz
POWER SUPPLY
WATER PUMP
POWER SUPPLY
WATER PUMP
POWER CONNECTION
2x2.5+2.5
2x2.5+2.5
2x2.5+2.5
2x2.5+2.5
2x2.5+2.5
2x4.0+4.0
2x4.0+4.0
2x6.0+4.0
2x6.0+4.0
4x2.5+2.5
4x2.5+2.5
4x2.5+2.5
4x2.5+2.5
4x2.5+2.5
3.8kW
4.5kW
5.6kW
7.8kW
9.5kW
12.5kW
14.0kW
17.0kW
21.0kW
14.0kW
17.0kW
21.0kW
26.0kW
31.0kW
220-240
220-240
220-240
220-240
220-240
220-240
220-240
220-240
220-240
3x380
3x380
3x380
3x380
3x380
10
10
10
16
16
16
20
32
32
10
16
16
16
25
3.9
4.6
5.8
7.6
9.4
10.4
12.6
17.0
20.0
4.8
6.3
8.8
9.8
11.4
Model
Voltage (V)
Fuse (A)
Current (A)
Cable diameter (mm )
2
(for max. Length of 20 meters)