8. Winter / Maintenance.
If or when it is decided to close down the swimming pool for the winter, and the pool pump and the heat pump
are turned off, it is extremely important that the heat pump is emptied for water
instantly
.
Loosening both adapters and let all water out.
Important.
Tilt the heat pump to 45º so all water is able to drain out from inside the heat exchanger.
Empty the pipes between the heat pump and technical room.
Do not leave this work for a later, because the frost always comes surprisingly.
The heat pump warranty does not cover any frost damage.
The heat pump may be left outside all the year round but if you do have some room for the heat pump in a shed
or in your garage, will this be a perfect place to keep it for the winter period. You may use a sack barrow/trolley
for the transport.
You may have a CCE socket mounted on the wall or on a stand
( electrician job )
at the location where the heat
pump is placed, the heat pump may then always easily be moved indoors in winter time (not a must). You may pull
a bag down over the heat pump – possibly using the plastic bag from the packaging.
Do
not
lay down the heat pump.
For optimal operation and efficiency, the heat pump should be given a clearance of at least 2 m above the top
blow-off. There must be a clearance of at least 1 m round the heat pump. The suction and/or the blow-off may
no way be impeded or blocked. To be checked regularly.
9. Control Panel and Functions.
The control panel is placed at the side of the heat pump, above the pipe connection.
Start/stop. Mode. Set. Aux.
10, Start-Up.
The control panel display shows all items of information required during operation and settings.
PS. This manual is primarily based on using the machine as a heat pump.
Switch on the main power supply to the heat pump.
Push start and await the display.
If the displays does not show SOL, push mode until the display shows
SUN.
If the water flow from the pool pump is effective, the heat pump will
start after about 2.45 minutes. (delayed start)
When the heat pump works, or waits under delayed star, the display
will show temperatures for the pool water IN/OUT.
See picture right.
Aux button is not in use.
Summary of Contents for 34-180505
Page 4: ...El diagram til 9 5kw 14kw ...
Page 6: ...6 Effektivitetskurver Kurver til 9 5 kw Varmepumpe ...
Page 7: ...Kurver til 14 kw Varmepumpe ...
Page 8: ...Kurver til 26 kw Varmepumpe ...
Page 12: ...Parameter ...
Page 17: ...Electricity PCB diagram for 9 5 14 kw ...
Page 19: ...6 Efficiency curves Curves for 9 5kw Heat pump ...
Page 20: ...Curves for 14kw Heat pump ...
Page 21: ...Curves for 26kw Heat pump ...
Page 25: ...The Parameters ...
Page 27: ...How the Heat pump works ...