background image

 

 

 

                                 

       WELL mPBX-U110R Installation Guide  

Default

 

SIP

 

UDP

 

port:

 

5060

 

There

 

are

 

6

 

extensions

 

set

 

up

 

by

 

default.

 

The

 

user

 

could

 

use

 

these

 

extensions

 

directly,

 

edit

 

or

 

delete

 

them.

 

Their

 

extension

 

numbers

 

are

 

“300”

“305”

 

(6

 

numbers

 

in

 

a

 

row)

 

whose

 

passwords

 

are

 

“pincode

 

+

 

respective

 

extension

 

number”.

   

4.2

 

Logging

 

in

 

the

 

Web

 

Configuration

 

Panel

         

Firstly,

 

please

 

check

 

if

 

the

 

IP

 

address

 

that

 

assigns

 

to

 

the

 

network

 

port

 

(LAN

 

or

 

WAN)

 

is

 

in

 

the

 

same

 

segment

 

with

 

the

 

PC

 

and

 

which

 

can

 

be

 

connected

 

when

 

commit

 

‘Ping

 

+mPBX

 

IP

 

address’

 

command.

 

Start

 

the

 

browser

 

on

 

PC.

 

In

 

the

 

address

 

bar,

 

enter

 

the

 

IP

 

address,

 

click

 

‘enter’

 

button

 

and

 

then

 

you

 

can

 

see

 

WELL

 

mPBX

U110R

 

Web

 

Configuration

 

Panel

 

login

 

page

 

(See

 

Figure

 

4

1).

             

 

 

Figure

 

4

1

 

mPBX

 

Web

 

Configuration

 

Panel

 

Login

 

Page

 

Enter

 

the

 

Admin

 

User

 

Name

 

and

 

Password

 

to

 

log

 

in.

   

 

Figure

 

4

2

 

mPBX

 

Admin

 

Configuration

 

Interface

 

Via

 

the

 

configuration

 

interface,

 

the

 

admin

 

can

 

make

 

all

 

the

 

system

 

configurations,

 

including

 

network

 

settings

 

(LAN,

 

WAN,

 

Firewall,

 

VPN,

 

DDNS,

 

VLAN,

 

etc.);

 

system

 

parameters

 

configuration

 

(system

 

prompts,

 

time

 

zone,

 

                                                                                                                             

10/13 

Summary of Contents for mPBX-U110R

Page 1: ...WELL mPBX U110R Installation Guide WELL mPBX U110R Installation Guide Version V1 0 Date 25th July 2012 1 13 ...

Page 2: ...Installation instructions 6 3 2 1 Connection of ethernet ports 6 3 2 2 Connection of E1 T1 ports 7 3 2 3 Connection of FXS ports 8 3 2 4 Power connection 9 3 2 5 Overall flow chart 9 4 WELL mPBX U110R basic configurations 9 4 1 Factory defaults 9 4 2 Logging in the web configuration panel 10 4 3 Network settings 11 4 4 Extensions and setup management 11 4 5 Configuring terminals 11 4 6 Making rece...

Page 3: ...ey are able to select their local language for Web GUI and Voice Prompt Furthermore it is renowned for its user friendly web configuration panel which is easy accessible and self evident making configuration a trouble free job This Guide explains how to install WELL mPBX U110R how to configure WELL mPBX U110R via web interface how to add extensions and make receive calls via PSTN lines 1 Preparati...

Page 4: ...WELL mPBX U110R Installation Guide 2 Hardware Specifications 2 1 Overview Figure 2 1 WELL mPBX U110R 2 2 LED Indicators and Ports Figure 2 2 WELL mPBX U110R Front Panel 4 13 ...

Page 5: ...etwork port for the connection to internet It supports DHCP server PPPoE dynamic DNS and static IP for IP address assignment E1 T1 ports For the connection to E1 line or the E1 port of traditional PBX Audio Input port For the connection to a music on hold source Audio output port For the connection to a paging system Reset Button Press the reset button to restore the factory defaults Please make s...

Page 6: ...and high frequency and high current devices Is using independent power junction box and effective anti grid interference measures have been taken Mechanical load Please make sure that the device is placed steadily to avoid any accident that might cause damage If placed on the desktop please ensure it is horizontally placed 3 2 Installation Instructions After placing WELL mPBX U110R in a suitable p...

Page 7: ...equence of E1 port From the above table we can see that the No 1 and No 2 pins of WELL mPBX U110R E1 port is for receiving data No 1 for receiving data No 2 for receiving data while No 4 and No 5 is for transmitting data No 4 is for transmitting data No 5 is for transmitting data When connected to the E1 line RX of E1 port should be connected to TX of E1 line RX of E1 port should be connected to T...

Page 8: ...ion Guide Figure 3 2 Connection of E1 T1 port 3 2 3 Connection of FXS ports The FXS port could be connected to an analog phone with a phone line The connection could be depicted as below Figure 3 3 Connection of FXS ports 8 13 ...

Page 9: ...cator lights would turn on Please switch off the power before plugging or unplugging the cables 3 2 5 Overall Flow Chart Figure 3 4 Overall Flow Chart 4 WELL mPBX U110R Basic Configurations 4 1 Factory Defaults WELL mPBX U110R provides web based configuration interface for administrator and account user The user can manage the device by log in the web interface The factory default IP address LAN 1...

Page 10: ... same segment with the PC and which can be connected when commit Ping mPBX IP address command Start the browser on PC In the address bar enter the IP address click enter button and then you can see WELL mPBX U110R Web Configuration Panel login page See Figure 4 1 Figure 4 1 mPBX Web Configuration Panel Login Page Enter the Admin User Name and Password to log in Figure 4 2 mPBX Admin Configuration ...

Page 11: ... Static IP address please select this option and enter the LAN parameters IP address subnet mask default gateway DNS etc 3 If mPBX is connected to ADSL adapter directly please select PPPoE option and enter the ADSL user name and password LAN Settings Click Network Settings LAN Settings on the left menu bar of the web configuration interface LAN port is used for the interoperability of IP terminals...

Page 12: ...by dialing the other s extension number 2 Outbound calls Firstly please connect a PSTN line to the first FXO port Then the default extensions are able to make outbound calls via this trunk by simply dialing 9 phone number The is Key as Send Note The dial pattern of the default outbound route is 9 But if the user has changed it please dial the new prefix instead of the digit 9 when making outbound ...

Page 13: ...e installation and basic settings of WELL mPBX U110R for making and receiving calls For more functionality and advanced settings of WELL mPBX U110R please refer to the relative documents as below WELL mPBX U110R Datasheet WELL mPBX U110R Administrator s Guide WELL mPBX U110R User s Guide The End ...

Reviews: