1-14
NOTE:
Replacing the burner rails requires completely tearing down the frypot and installing new frypot
insulation. Refer to the frypot exploded view below for component identification.
1.
Remove the frypot per Section 1.9.11.
2.
Remove the burner assemblies (1).
3.
Remove insulation retainers and blanket insulation (2).
4.
Remove the upper oil zone insulation bracket and upper oil zone insulation (3).
5.
Remove the plenum (4).
6.
Remove the front lower combustion chamber insulation retainer and insulation (5), and the front lower
combustion chamber inner insulation retainer and insulation (6).
NOTE:
Full-vat units have two-piece
insulation retainer and insulation components. Dual-vat units have one-piece components.
7.
Remove the upper combustion chamber insulation retainer and insulation (7).
8.
Remove the inner upper combustion chamber insulation retainer and insulation (8).
9.
Remove the rear lower combustion chamber retainers, back, and insulation (9).
NOTE:
Full-vat units have
two-piece backs and four retainers. Dual-vat units have one-piece backs and two retainers.
10.
Remove the flue assembly (10).
Disassembling A Frypot
(Full Vat Illustrated)
Spacers
Spacer
10
2
3
4
5
6
7
8
1
11
9
See page 1-16 for reassembly illustration.
11.
Remove the upper burner rails (11).
NOTE:
For the following steps, refer to the frypot exploded view on
page 1-16 for component identification.
12.
Remove any residual insulation, sealant, and/or oil from the exterior of the frypot.
13.
Place the “L” shaped pieces of the combustion chamber insulation (1) in the front and rear corners of both
upper rail-retaining slots. (See page 1-16).
14.
Using a mallet and short piece of wood, tap the corner tabs of the combustion chamber over the insulation
to ensure a solid seal of the burner.
15.
Install the upper burner rails (2) with the heat deflectors slanting toward the rear of the frypot. The rails
will cover the “L” shaped pieces of combustion chamber insulation previously installed.
Summary of Contents for Frymaster FilterQuick 2FQG30U
Page 8: ...1 3 ...
Page 41: ...1 36 1 16 2 Bulk Wiring ...
Page 56: ...1 51 1 18 6 Clogged Drain Failed Oil Sensor Error Flowchart ...
Page 57: ...1 52 1 18 7 Menu Trees 1 18 7 1 FilterQuick Controller Setup Menu Tree ...
Page 58: ...1 53 1 18 7 2 FilterQuick Filter and Info Mode Menu Tree ...
Page 62: ...1 57 1 20 Principal Wiring Connections ...
Page 63: ...1 58 1 21 Wiring Diagrams 1 21 1 Main FQG 230 430 120V CE Export ...
Page 64: ...1 59 1 21 2 Main FQG 230 430 Australia ...
Page 65: ...1 60 1 21 3 Main FQG 230 430 120V CE Export with Solid Shortening ...
Page 66: ...1 61 1 21 4 Main FQG 230 430 Australia with Solid Shortening ...
Page 67: ...1 62 1 21 5 Main FQG 330 530 120V CE Export ...
Page 68: ...1 63 1 21 6 Main FQG 330 530 Australia ...
Page 69: ...1 64 1 21 7 Main FQG 330 530 120V CE Export with Solid Shortening ...
Page 70: ...1 65 1 21 8 Main FQG 330 530 Australia with Solid Shortening ...
Page 71: ...1 66 1 21 9 Transformer Filter Box 430 530 ...
Page 73: ...1 68 1 22 2 FilterQuick FQG30 Series Simplified Wiring with Push Buttons ...
Page 74: ...1 69 1 22 3 FilterQuick FQG30 Series Data Network Flowchart ...
Page 76: ...1 71 1 24 Shortening Melting Unit Wiring Diagram ...
Page 77: ...1 72 1 25 Modular Basket Lift Wiring Diagram 100 120V 1 2 4 3 5 6 12 7 8050518E ...