11. Other information - Cleaning
Page 146
105204
– WTS-300-E - V4.1 - 20.01.2022
11.
Other information - Cleaning
11.1 Detergent supply via beaker
Option 1: Usage of the 'alkaline detergent' function
‘
If parameter [r21 = 0] is set, only the relay for alkaline detergent is activated. The
selection of the cleaning agent (alkaline / acidic) is up to the farmer.
Option 2: Usage of the 'Hot water valve' function
‘
Assign function 16 'Hot water valve / beaker cleaning' to one of the relays A1..A20.
Select the hot water valve for the main cleaning in parameter [r53].
NOTE: By activation of parameter [n30] (water intake via level) the hot water valve
to flood the beaker when the level is achieved would be switched off again.
With the beaker dosing a premature switching off of the rinsing pump may be nec-
essary, i.e. prior to the finishing of the dosing process. This can be set in parameter
[r22].
11.2 Setting of a break in the cleaning programme
During the automatic cleaning programme it is possible to add a break after a clean-
ing cycle.
Example: Setting a break after the pre-cleaning until sufficient quantities of warm
water from the heat recovery for the main cleaning cycle is available.
The following settings are necessary
After which cleaning cycle the break shall take place [r71]
How the break shall be finished [r70]
Options:
When the break should be finished ...
- ... via a signal at the digital input
assign the function 15 "Start from rinse stop" to a digital input A21 to A28.
- ... after a certain amount of time
enter this time in parameter [r72].
- ... at a certain time
enter them in parameter [r73].
A parameterized elapsed time of the break or the countdown-timer is displayed al-
ternately with “STOP”.
NOTICE