3. Do not allow pump to run dry.
4. If flow of water to pump inlet is restricted such as when used with a control valve: Do not
run pump continuously; run at intervals (turn the pump off for 10 minutes after the pump
runs continuously for 1 hour). Do not shut down the pump over 24 hours.
5. Pump must be installed in horizontal position only (outlet facing upward).
6.
Pump motor and terminal box are not waterproof.
Water should not come
in contact with motor or terminal box.
7. Drain pump if temperature falls below freezing.
Wiring Instructions
WARNING:
Make sure cord set is not plugged into an outlet during initial set-up
and wiring.
1. Prepare a three core electric cord set
with plug.
2. Loosen the screws on the black plastic box
on the top of the pump.
3. When you open the plastic box on the top
of the pump, you will find the short electric
cord is already in place. Take out the electric
cord any lay the new electric cord back.
4. Loosen the ground screw marked with “ ”
and fasten the ground wire on to it.
5. Put back the black wiring kit cover and
screw it tight.
Priming The Pump
Pump must be filled with water before starting. This must be done after the pump is installed
and all pipes connected.
1. Unscrew the nut on top of pump body next to
inlet pipe.
2. Fill pump with clean water.
3. Replace nut and tighten.
5
L
N
G
R
O
U
N
D
Capacitor
nut