BIRD LAZZZER V20062011
DESCRIPTION
31.
ON-OFF SWITCH:
used to turn the appliance on/off
32.
FUSE:
1 A/250 V AC slow
33.
SECTOR POWER-SUPPLY INPUT:
IEC socket with integral fuse. Connect the
power-supply cable provided to this socket.
34. EARTH
35.
INTERLOCK INPUT:
provides the facility to connect an emergency stop button to
the appliance (optional). By pressing this button, the laser beam will immediately
cut out.
36.
KEY-OPERATED ON-OFF SWITCH:
used to activate / deactivate the laser. Use
the keys to ensure that only experienced operators are able to turn the laser on.
37.
COOLER AIR-VENT:
used to cool components inside the appliance case. Ensure
that this air-extractor vent is never covered up.
38.
SAFETY HOOK:
used to attach a safety cable when the appliance is suspended.
(refer to paragraph on installing at a height)
39.
POWER-SUPPLY LED:
shows when the appliance is turned on.
40.
LED LASER:
flashes during the laser’s off phase (15 minutes)
41.
LASER OUTPUT:
the laser beam leaves the appliance here. Be sure NEVER TO
LOOK INSIDE the appliance through this window while the laser is turned on.
42.
WARNING LABEL:
Warning
– Laser class 3B. Laser radiation if open. Avoid
exposure to laser beams.
43.
LASER WARNING SYMBOL:
warns that the laser is potentially dangerous when it
is not used by a specialist operator.
44.
DISPLAY:
displays time remaining: 900 seconds laser on / 900 seconds laser off.
45.
SUPPORT BRACKET:
with handles on both sides to suspend the appliance, and 1
fixing hole to secure a mounting bracket.
INSTALLING AT A HEIGHT
Important: lnstallation is to be carried out only by qualified personnel.
Incorrect installation can cause severe injuries and/or damage the
appliance. High-level installation requires experience! Load limits