WK Burners                        up to 32,000 kW

These industrial burners of modular 
construction are adaptable, robust and 
powerful.
Even on the toughest industrial applications
these oil, gas and dual fuel burners operate
reliably.

WKmono 80 Burners           up to 17,000 kW

The WKmono 80 burners are the most 
powerful monoblock burners from Weishaupt. 
They are available as oil, gas or dual fuel 
burners and are designed for tough industrial
application.

The complete program:
Reliable technology and prompt, professional service

W Burners

up to 570 kW

The compact burners, proven millions of times
over, are economical and reliable. Available as
gas, oil and dual fuel burners for domestic and
commercial applications.
The purflam

®

burner version with special 

mixing head gives almost soot-free combustion
of oil with greatly reduced NOx emissions.

monarch

®

WM Burners

and Industrial Burners        up to 11,700 kW

These legendary industrial burners are durable
and versatile.
Numerous variations of oil, gas and dual fuel
burners meet a wide range of applications and
capacity requirements.

MCR Technology / Building Automation
from Neuberger

From control panels to complete building man-
agement systems - at Weishaupt you can find
the entire spectrum of modern control 
technology. Future orientated, economical and
flexible.

Service

Weishaupt customers can be assured that 
specialist knowledge and tools are available
whenever they are needed. Our service 
engineers are fully qualified and have 
extensive product knowledge, be it for burners,
heat pumps, condensing boilers or solar 
collectors.

Max Weishaupt GmbH · 

88475 Schwendi

Weishaupt close by? Addresses, telephone numbers etc. can be found
at  www.weishaupt.de

We reserve the right to make changes. All rights reserved.

Water heaters/Energy storage

The diverse program of potable water and
energy storage for various heat sources
includes storage volumes of 70 to 3,000 litres.
In order to minimize storage losses, potable
water cylinders from 140 to 500 litres are
available with highly efficient insulation using
vacuum insulation panels.

Solar systems

The stylish flat-plate collectors are the ideal
complement for any Weishaupt heating 
system. They are suitable for solar water 
heating and for combined heating support.
With versions for on-roof, in-roof and flat roof
installations, solar energy can be utilised on
almost any roof.

Wall-hung condensing boilers
for gas                                    up to 240 kW

The wall-hung condensing boilers WTC-GW
have been developed to meet the highest
demands in ease of operation and efficiency.
Modulating operation means these units 
operate quietly and economically. 

Floor-standing condensing boilers
for oil and gas

up to 1,200 kW

The floor-standing condensing boilers 
WTC-GB (up to 300 kW) and WTC-OB 
(up to 45 kW) are efficient, low in pollutants
and versatile in use. 
Even the largest capacities can be covered by
cascading up to four gas condensing boilers.

Heat pumps                            up to 180 kW

The heat pump range offers solutions for the
utilisation of heat from the air, the soil or
ground water.
Some systems are also suitable for cooling
buildings.

Geothermal probe drilling                             

With its daughter company, BauGrund Süd,

Weishaupt also offers geothermal probe and
well drilling. With the experience of more than
10,000 systems and more than 2 million meters
of drilling, BauGrund Süd offers a 
comprehensive service program.

Summary of Contents for WWP-RG1

Page 1: ...Installation and operating instruction Room device WWP RG1 83316002 1 2019 08 ...

Page 2: ...data 7 3 2 1 1 Electrical data 7 3 2 2 Ambient conditions 7 3 2 3 Dimensions 7 4 Installation 8 5 Operation 10 5 1 Display and operating unit 10 5 2 Display 11 5 2 1 Display room humidity 11 5 3 ManualOperation 12 5 4 Absence 12 5 5 Party mode 13 5 6 Automatic operation 13 5 7 Set room setpoint temperature 14 5 8 Service level 15 5 8 1 Check assignment 15 5 8 2 Adjusting the room temperature 15 5 ...

Page 3: ...llowing requirements apply This appliance can be used by children 8 years and above as well as by persons with limited physical sensory or mental capacities or lack of experience and know ledge provided they are supervised or have been instructed regarding the safe use of the appliance and understand the resulting danger Children must not play with the appliance Cleaning and operator maintenance m...

Page 4: ... be attributed to one or more of the following causes non approved application non observance of the manual operation with faulty safety equipment continual operation despite a fault improper installation commissioning operation and service repairs which have been carried out incorrectly the use of non original Weishaupt parts force majeure the installation of additional components which have not ...

Page 5: ...ces can be assigned to a heating circuit The device should only be used indoors The installation location must comply with local regulations and must be frost proof Improper use could endanger the health and safety of the user or third parties cause damage to the unit or other material assets 2 2 Safety measures Safety relevant fault conditions must be eliminated immediately 2 3 Disposal Dispose o...

Page 6: ...Installation and operating instruction Room device WWP RG1 3 Product description 83316002 1 2019 08 La 6 20 3 Product description 3 1 Type key WWP RG1 WWP Series Weishaupt heat pump RG1 Type room device ...

Page 7: ...rical data Voltage supply via Bus line Consumption max 0 7 W Type of protection IP20 3 2 2 Ambient conditions Temperature in operation 0 50 C Temperature during transport storage 0 50 C relative humidity max 85 no dew point Installation elevation max 2000 m 1 1 Consultation with Weishaupt is required for higher installation elevation 3 2 3 Dimensions 80 mm 80 mm ...

Page 8: ...er supply prior to starting any work Safeguard against accidental restart CAUTION Damage to the PCB due to electrostatic discharge ESD PCB can be damaged by contact Do not touch the PCB and its components The electrical connection must only be carried out by qualified electricians Ob serve local regulations Secure wall bracket 1 to the wall using the screws supplied Feed the wires 2 through and co...

Page 9: ... and operating instruction Room device WWP RG1 4 Installation 83316002 1 2019 08 La 9 20 Insert the lugs 1 of the room device into the recesses 2 Click room device into place downwards 1 2 Pull off protective foil ...

Page 10: ...ing unit 2 3 5 1 4 Keys 1 Manual Operation ch 5 3 2 Absent ch 5 4 3 Party mode ch 5 5 4 Automatic operation ch 5 6 Dial knob 5 turn select or change values press briefly confirm or save values In setting mode approx 3 seconds exit value without saving back to standard display In standard display approx 3 seconds display room humidity ...

Page 11: ...e activated increased temperature level 7 Fault 1 8 Current room temperature standard display parameters and values 9 Setting mode activated 0 Service level activated Faults 1 If there is a fault in the system a flashing warning symbol appears in the dis play Notify your heating contractor or Weishaupt Customer Service 5 2 1 Display room humidity Current room humidity at the room device Press dial...

Page 12: ...operation Confirm operating mode using the dial knob The operating mode selected is active after approx 3 seconds Example Activate permanent setback operation 5 4 Absence The heating mode can be temporarily interrupted maximum 12 hours During the time set setback operation is activated Press Absence The hour display is displayed flashing Set and confirm hours required using the dial knob After app...

Page 13: ...s active for the time set Example Activate party mode comfort mode for 4 hours Once the time set has elapsed the operating mode previously set is active again Display the time remaining Press Party mode The time remaining is displayed flashing The standard display re appears after approx 30 seconds 5 6 Automatic operation Temperature level according to predetermined time program The time programs ...

Page 14: ...al knob Display changes to the the setting of the room setpoint temperature The room setpoint temperature set is displayed flashing Set and confirm the required room temperature using the dial knob Room setpoint temperature has been changed Example Increase room setpoint temperature in normal operation from 21 0 C to 22 0 C Following a change the room setpoint temperature at the respective tempera...

Page 15: ...ing unit of the heat exchanger The standard display re appears after approx 30 seconds 5 8 2 Adjusting the room temperature If no optimal placement of the room device is possible or a measurement error is to be compensated the measured room temperature can be adjusted Setting range 5 0 5 0 K Factory setting 0 0 Press Manual operation and Automatic operation simultaneously for ap prox 2 seconds The...

Page 16: ... Set and confirm value required using the dial knob The value has been saved The standard display re appears after approx 30 seconds 5 8 4 Set brightness in standby mode Adjust the brightness of the display in standby mode Setting range 0 30 Factory setting 0 Press Manual operation and Automatic operation simultaneously for ap prox 2 seconds The service level is activated Turn dial knob until para...

Page 17: ...nd operating manual of heat pump The room device must be assigned to a heating circuit If the room device has already been assigned to a heating circuit the standard dis play appears Assign room device Select and confirm heating circuit required using the dial knob Standard display appears Example room device is assigned to heating circuit 1 ...

Page 18: ... not find the heating circuit assigned a fault message ap pears indicating the heating circuit Example Fault heating circuit 1 Activate heating circuit Select expert level Select the relevant heating circuit Select Settings Select Function Activate heating circuit The heating circuit is activated the fault message disappears ...

Page 19: ...ion 8 Electrical data 7 F Fault 18 Faults 11 G Guarantee 4 H Humidity 7 I Illumination 16 Installation elevation 7 Installation location 5 K Key 10 L Liability 4 Light 16 Lockout 11 18 M Manual operation 12 Measurement error 15 O Operating panel 10 Operating unit 10 P Party mode 13 Protective foil 9 R Room humidity 11 Room sensor 15 Room setpoint temperature 14 Room temperature 15 S Safety measure...

Page 20: ...Weishaupt GmbH 88475 Schwendi Weishaupt close by Addresses telephone numbers etc can be found at www weishaupt de We reserve the right to make changes All rights reserved Water heaters Energy storage The diverse program of potable water and energy storage for various heat sources includes storage volumes of 70 to 3 000 litres In order to minimize storage losses potable water cylinders from 140 to ...

Reviews: