Set pump pressure
The pump pressure must be set according to the nozzle selected [ch. 4.2].
Check pump pressure at pressure gauge.
Set pressure using pressure regulating screw
1
:
increase pressure: clockwise rotation,
decrease pressure: anticlockwise rotation.
1
Press [+] key.
Burner drives to operating point P
1
.
Press [+] key.
Burner drives to operating point P
9
.
Adjust P
9
Select speed at full load as low as possible, but not less than 80 %. In doing so:
- observe flame stability,
- maintain mixing pressure required [ch. 7.1.3].
Check combustion values
Determine combustion limit [ch. 7.5].
Set excess air via air damper setting and speed.