Installation and operating instruction
Gas burner WG30…/1-C ZM-LN
3 Product description
83299902 1/2019-02 La
19-124
3.4.6 Rating
Combustion heat rating
Natural Gas
Liquid Petroleum Gas
40 … 350 kW
60 … 350 kW
Combustion head
WG30/1-LN
Capacity graph
Capacity graph to EN 676.
The capacity data given relates to an installation elevation of 0 m above sea level.
For installation elevations above 0 m a capacity reduction of
approx. 1 % per 100 m applies.
A limited capacity graph is valid for ducted air intake.
Combustion heat rating at combustion head setting:
Natural Gas
Liquid Petroleum Gas
Combustion head OPEN
3
5
Combustion head CLOSED
4
6
5
4
6
3
1
2
-1.0
-1.5
-0.5
0
0.5
1.0
1.5
2.0
325
400
375
350
300
275
200
175
150
125
100
75
50
25
0
2.5
3.0
3.5
250
225
1
Combustion heat rating [kW]
2
Combustion chamber pressure [mbar]