background image

 

5

Safety Instructions 

Overview 

This section states the safety instructions, which must be followed when installing, 
operating and servicing the MT-608S. If neglected, physical injury and death may 
follow, or damage may occur to controller and related equipment. The material in this 
chapter must be studied before attempting any work on, or with, the unit. 

Warnings and Notes 

This manual distinguishes safety instructions. Warnings are used to inform of 
conditions, which can, if proper steps are not taken, lead to a serious fault condition, 
physical injury or death. Notes are used when the reader is required to pay special 
attention or when there is additional information available on the subject. Notes are 
less crucial than warnings, but should not be disregarded. 

Warnings 

Readers are informed of situations that can result in serious physical injury 
and/or serious damage to equipment with the symbol shown to the left. A 
Warning symbol indicates that the reader should pay special attention to the 
accompanying text. Precautionary steps should be taken to insure that the 
installation is in compliance with warnings. Warnings include hazardous 
conditions that could cause personal injury or equipment damage if care is 
not taken. The text next to this symbol describes ways to avoid the danger. 
 

Warnings 

Dangerous Voltage Warnings:

 Warns of situations in which high voltage 

can cause physical injury and or damage equipment.   

General warning:

 Warns of situations, which can cause physical injury and 

or damage equipment by means other than electrical.   

Electrostatic Discharge Warning:

 Warns of situations in which an 

electrostatic discharge can damage equipment. 

Readers are notified of the need for special attention or additional in formation 
available on the subject with the following symbols: 

CAUTION! 

Aims to draw special attention to it. 
 

Note:

 

Note: 

gives additional information or points out more information available 

on the subject. 

Summary of Contents for EasyView MT-608S

Page 1: ...MT 608S RISC based operator interface terminal with 7 7 flat panel display User s Manual...

Page 2: ...11 2 2 4 Safety Guidelines 11 2 3 Communications Connections 13 2 3 1 Connector COM 1 RS232 13 2 3 2 Connector COM2 RS232 14 2 3 3 Connector COM3 RS485 14 2 3 4 USB Client port 15 2 3 5 USB Host port...

Page 3: ...3 3 4 Application program development 29 3 4 1 Microsoft eMbedded Visual C 4 0 29 3 4 2 MT608 SDK 30...

Page 4: ...thus subject to change without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Weintek Labs Inc Inf...

Page 5: ...mage to equipment with the symbol shown to the left A Warning symbol indicates that the reader should pay special attention to the accompanying text Precautionary steps should be taken to insure that...

Page 6: ...ith Windows CE OS The built in Windows CE OS platform forms a bridge that lets MT608S be an open HMI solution for system integration Features z Built in flash memory and Windows CE OS inside z All in...

Page 7: ...angle 40 30 50 50 T B R L z Luminance cd m2 150 z Storage temperature C 20 60 z Operating temperature C 0 45 z Backlight CCFLx2 z Contrast ratio 30 1 Touch screen z Type 4 wire analog resistive z Res...

Page 8: ...ls with a depth of 4 105mm It is recommended that the unit be mounted on the front panel of a steel enclosure through an appropriate opening Allow a clearance of 1 25mm around the sides of the unit fo...

Page 9: ...s vapors or dusts z The unit should not be installed where fast temperature variations and or high humidity are present This will cause condensation of water in the device z Do not install these termi...

Page 10: ...ons Caution Supply Voltage Condition Do not power the MT 600 and inductive DC loads or input circuitry to the controller with the same power supply Note The 24 VDC output from some controllers may not...

Page 11: ...be connected to a tree from a central star earth ground point This ensures that no ground conductor carries current from any other branch 2 2 3 CE Requirements To make an MT 600 comply with EMC direc...

Page 12: ...rsonnel ICS 3 304 81 Safety Recommendations Consideration should be given to the use of an emergency stop function which is independent of the programmable controller Where the operator is exposed to...

Page 13: ...h communication Shielded cable must be used for long lengths or cables run in an electrically noisy environment Do not run cables next to AC power lines or near sources of electrical noise Be sure tha...

Page 14: ...5 GND Signal Ground 6 7 RTS Ready to send output 8 CTS Clear to send input 9 Pin 1 6 8 is short 2 3 3 Connector COM3 RS485 Pin Designations COM3 RS 485 Pin assignment of the 9 Pin Female SUB D COM3 R...

Page 15: ...ceive 4 Rx Tx RS485 Transmit 5 Rx Tx RS485 Transmit 6 GND GND 2 3 4 USB Client port The USB client port for ActiveSync use a USB client to USB host cable connects the USB client port on MT608 and the...

Page 16: ...o upper left lower left lower right and upper right corners When all five are done the will disappear The Touch Screen parameter will store at Flash Rom z Boot Loader mode Load new Windows CE image fi...

Page 17: ...atisfactorily in electromagnetic noise immunity and without emitting high levels of electrical noise into the environment emission The units are designed to meet European Community standards when inst...

Page 18: ...18 2 5 Dimensions of MT 608S Cutout dimensions MT 608S 222mm 8 74 W x 167mm 6 57 H Side View Front View Bottom View...

Page 19: ...sh slot h USB Master b Sound ports i Com1 RS232 c MIC ports j Com2 RS232 d Ethernet port RJ 45 k Com3 RS485 e Fuse l Dip Switch f Power connector m Contrast Adjust VR g USB client Rear View k j i d e...

Page 20: ...ion of smart mobile and small footprint devices With a complete operating system feature set and end to end development environment Windows CE NET contains everything you need to create a custom Windo...

Page 21: ...Tap this icon by the stylus to activate hide this Soft keyboard 3 2 2 System Settings MT606 provides an integrated utility for users to make basic setting of the machine Step 1 Tap the cecp icon from...

Page 22: ...age of the cecp provides the function to turn off the LCD backlight and thus elongates the period of service For example if the user wants the backlight turned off automatically after 10 minutes when...

Page 23: ...istry data to the IPSM folder Next time reboot the MT608S Windows CE system will use the stored registry data System version Show current CE image version Set serial port mode Set Com3 RS485 2W 4W mod...

Page 24: ...ce From Jan 2005 the MT608S without USB Host Don t set the CECP USB Host to Enable The MT608S will can not startup 3 2 3 IPSM IPSM Intel Persistent Storage Manager The IPSM serves as a small capacity...

Page 25: ...an also pass parameters into the linked target By default a lnk file uses the following format number of ASCII characters after pound sign command line optional parameters For example to start MyApp e...

Page 26: ...og box type your user name password and domain if required and then click OK The Remote Desktop window will open and you will see the desktop settings files and programs that are on your office comput...

Page 27: ...p Connections 3 Find the default device name Change it to a unique one depending on the plan of individual LANs LAN90001 4 If the MT608S is a node of a LAN with DHCP servers it is now available 5 If t...

Page 28: ...CE boot up don t connect the USB cable 3 Connect the USB client port of the MT 608S and the USB host port of the host PC by the USB client to USB host cable 4 When the Add New Hardware Wizard asks fo...

Page 29: ...ws CE application programs are only portable in the source code level Users must rebuild the runtime file for a different Windows CE platform even though the source code may not be changed at all The...

Page 30: ...s to an extensive set of functions that are specific to the MT606 hardware Step Installing the MT608S SDK 1 Download or from MT608S SDK CD find the HMI_MT608_SDK msi file Double click the file s name...

Page 31: ...31...

Reviews: