background image

V2.00

 

1.7

 

LED indicator 

LED indicators show the operation status of cMT-SVR. 

Power (Orange) 

Indicates power status. 

CPU (Green)

 

Indicates CPU status. 

Communication (Blue) 

Indicates communication status. It flashes during communication and 
may stay on when communication is good. 

1.8

 

CR1225 battery 

The cMT-SVR Series HMI requires a CR1225 coin type lithium battery to keep the RTC running. 
Battery type: CR1225 3V lithium battery 

1.9

 

Power connection 

Power:

 The unit can be powered by DC power only, voltage range: 24

±

20% Volts DC, compatible 

with most controller DC systems. The power conditioning circuitry inside the unit is accomplished 
by a switching power supply. The peak starting current can be as high as 500mA. 

Note: 

Connect positive DC line to the

+

terminal and the DC ground to the

-

terminal. 

1.10

 

How to update cMT-SVR OS image 

Copy the MTfirmware.bin file to SD card, insert the SD card to cMT-SVR and flip DIP Switch 2 to ON. 

Restart cMT-SVR and wait about 2 minutes for the system to update OS image. 

cMT-SVR Startup Guide 

Summary of Contents for cMT-SVR

Page 1: ...User Manual cMT SVR Startup Guide...

Page 2: ...connection 4 1 10 How to update cMT SVR OS image 4 1 11 Requirements 5 Chapter 2 System Setting 6 2 1 cMT SVR System Setting 7 2 1 1 Information 7 2 1 2 System Setting 8 Chapter 3 How to create a cMT...

Page 3: ...B Client N A Ethernet 10 100 1000M x 2 COM Port COM1 RS232 COM2 RS485 2W 4W COM3 RS 485 2W CAN Bus N A HDMI N A RTC Built in CR1225 3V lithium battery Power Input Power 24 20 VDC Power Consumption 230...

Page 4: ...et 2 Port f SD Card Slot c Ethernet 1 Port g DIP Switch d Com1 RS 232 Com2 RS 485 2W 4W Com3 RS 485 2W h Reset Button 27 00 1 063 125 00 4 921 114 80 4 520 129 73 5 107 5 107 Front View Side View Side...

Page 5: ...rts The LED indicators on the Ethernet port indicate Orange LED LAN link status Green LED Active communication status 1 6 DIP switch Each unit is equipped with a reset button and a set of DIP switches...

Page 6: ...hium battery 1 9 Power connection Power The unit can be powered by DC power only voltage range 24 20 Volts DC compatible with most controller DC systems The power conditioning circuitry inside the uni...

Page 7: ...wnload cMT Viewer application from App Store or Google Play 6 Wireless router The cMT SVR connects with other devices through wires To connect an iPad or an Android device with cMT SVR use a wireless...

Page 8: ...rowser IE Chrome or Firefox and enter cMT SVR IP address for example 192 168 1 15 web_ihmi to configure cMT SVR Set on iPad or Android device Install and open cMT Viewer App on iPad or Android device...

Page 9: ...V2 00 7 2 1 cMT SVR System Setting 2 1 1 Information The following part introduces cMT SVR system information cMT SVR Startup Guide...

Page 10: ...duces cMT SVR system setting There are two modes System setting and Update System Setting controls all the settings while Update controls limited items For safety confirm password before configuring A...

Page 11: ...of Ethernet 1 and Ethernet 2 The default IP address of Ethernet 1 is DHCP The default IP address of Ethernet 2 is 192 168 100 1 Date Time Set RTC time or select Sync with host to synchronize PC time...

Page 12: ...I Name Enter a cMT SVR name to identify the unit when transferring data This saves the trouble of remembering the IP address of each cMT SVR History Clear and backup history data in cMT SVR cMT SVR St...

Page 13: ...V2 00 11 Email Set the mail address and group of the Email contact Project Management Restart cMT SVR project and restore to initial state or update and backup project file cMT SVR Startup Guide...

Page 14: ...2 00 12 System Password Set the password for login and the password for transferring project file and history file Enhanced Security Set the privilege and password of the account cMT SVR Startup Guide...

Page 15: ...create a cMT SVR project 3 1 Create a new project Step 1 Launch EasyBuilder Pro and select cMT SVR model Step 2 Create the needed objects on editing screen Step 3 Save the project and compile to cxob...

Page 16: ...Ethernet Or in cMT SVR System setting tap Project Management Update Project to transfer project file from PC to cMT SVR Open internet browser IE Chrome Firefox enter cMT SVR IP address for example 192...

Page 17: ...he cMT SVRs that logged in before Setting tab is used to adjust the volume or enable Auto Lock feature on client end If needed switch languages here After changing the language log in cMT Viewer App a...

Page 18: ...16 4 2 How to load project file to the client device Step 1 Start cMT Viewer App tap Start Button as shown in the following figure Step 2 Search all the cMT SVRs on the same network cMT SVR Startup G...

Page 19: ...V2 00 17 Step 3 Select the cMT SVR tap and then enter password Step 4 The client device displays the project after the project is loaded cMT SVR Startup Guide...

Page 20: ...the preceding steps to search cMT SVR and load the project The badge is displayed in the icons of the successfully connected cMT SVRs Up to three cMT SVRs can log in the client device simultaneously a...

Page 21: ...V2 00 19 4 1 How to switch between cMT SVR projects When multiple cMT SVRs are connected to switch between cMT SVR projects select from Project tab To delete cMT SVR project tap cMT SVR Startup Guide...

Reviews: