background image

© weinor GmbH & Co. KG 

10 | EN 

© weinor GmbH & Co. KG 

EN | 11

Pressing the selection button in the central channel for longer 
(approximately 1 second) changes the Auto or Manual operating 
mode for 

all the individual channels

. A different operating mode 

for individual channels (auto and manual) is set on switching for all 
channels to Auto operating mode.

Programming the transmitter

Requirement

The receiver is installed. 

Check whether the channel has been 

deleted

Stand in front of the blind to be programmed while programming.

1.  With receivers which have already been installed, switch the 

circuit breaker off and on again after a few seconds.
The receiver is now in programming mode for about 5 minutes.

2.  Press the programming button 

P

 on the back of the unit brie

fl

 y 

(approximately 1 second) until the status display lights for a 
short time. The blind moves up and down for approximately two 
minutes, showing that the receiver is in programming mode.

3. Press the 

UP

 button as soon as the blind starts moving in Open 

direction (within 1 second at the most). The status display lights 
brie

fl

 y.

The blind stops brie

fl

 y, starts moving again, stops and then 

moves in the Down direction.

4.  Immediately (within no more than 1 second) after down travel 

has started, press the 

DOWN

 button. The status display lights 

brie

fl

 y. The blind stops. The transmitter channel is programmed.

Note

The blind must be programmed again if it does not stop.
A bidirectional programming process in the hand-held 
transmitter can be cancelled by pressing the 

STOP

 button for 

6 seconds.

Group control unit

A group is understood to mean the control of several receivers 
at the same time. The selected group is controlled by a travel 
command. All 5 channels (transmitter) can be used for the group 
control.
Any number of receivers can be programmed and controlled in each 
channel. 

Selection button

Pressing the selection button brie

fl

 y allows you to select from 

5 channels. The various channels are indicated by the LEDs in the 
channel indicator lighting up.
An additional channel is reserved for the central channel to which 
all the individual channels are assigned automatically. When 
the central channel is selected, this controls all radio channels 
simultaneously. This is indicated by all 

fi

 ve LEDs lighting up.

Pressing the selection button brie

fl

 y allows you to query the 

current status (automatic/manual) of the programmed receivers 
(bidirectional receivers only) and the hand-held transmitter.
Pressing the selection button for longer (approximately 1 second) 
switches off automatic mode of the current bidirectional channel. 
The operating mode indicator lights up red. 

 The receiver now 

only carries out manual travel commands and does not respond to 
automatic travel commands.

Note

Upward travel of the receiver is initiated when the automatic 
system is activated.

Pressing the selection button for longer (approximately 1 second) 
switches on automatic mode of the bidirectional channel. The 
operating mode indicator lights up green. 

 The receiver now 

executes automatic and manual travel commands.

Explanation of functions

0800 328 6250

www.samsondoors.co.uk

0800 328 6250

www.samsondoors.co.uk

Summary of Contents for BiEasy 1M

Page 1: ...68 915 MHz 28245 0001 28246 0001 28247 0001 28245 0901 28246 0901 28247 0901 0682 Operating instructions translation 181226701_EN_1113 BiEasy 5M 0800 328 6250 www samsondoors co uk 0800 328 6250 www s...

Page 2: ...it is incorrectly installed or operated The unit contains small parts which can be swallowed Transport You must not use a unit that you have received in a damaged condition despite proper packaging Co...

Page 3: ...f the system must remain visible during operation if one or more transmitters are used for controlling the system Keep control systems out of the reach of children and the disabled Dispose of used bat...

Page 4: ...DIP switch 2 Mounting of wall bracket The wall bracket must be fixed so that the holes drilled avoid any electrical cables Before installing the unit in the required position check that the transmitte...

Page 5: ...or the radio range will be reduced by the reduction in the performance of the battery If the voltage drops below 2 V functions are no longer executed and nothing is displayed Explanation of functions...

Page 6: ...mitter can be cancelled by pressing the STOP button for 6 seconds Group control unit A group is understood to mean the control of several receivers at the same time The selected group is controlled by...

Page 7: ...eivers are connected to the same supply line then all are simultaneously in programming mode for approximately 5 minutes after the mains power is switched on If the P button on the transmitter is now...

Page 8: ...gaps open or the slats turn Keep the UP button pressed during the movement Approaching end positions of roller shutter awning Venetian blind Requirement The transmitter transmitter channel is program...

Page 9: ...1 OEM settings 2 Also press the STOP button The blind stops The status display lights briefly The ventilation position tilting position is programmed Approaching intermediate position Requirement The...

Page 10: ...e of fault Unusual events occurring prior to fault Accompanying conditions Own suspicion Battery replacement Note Replace batteries only with batteries of the identical type 1 Unscrew the underside of...