25
During servicing below listed parts are liable to be removed and
give access to potentials above 250V to earth.
1. Magnetron
2. High voltage transformer
3. High voltage capacitor
4. High voltage diode
5. High voltage fuse
The following conditions may cause undue microwave
exposure during servicing.
Improper fitting of magnetron;
Improper matching of door interlock, door hinge and door;
Improper fitting of switch support;
Door, door seal or enclosure has been damaged.
1. If LED displays Err0 during working, it indicates that sensor
has been short circuit and you need replace it at the nearest
repaired department.
2. If LED displays Err1 during working, it indicates that sensor
has been open circuit and you need replace it at the nearest
repaired department.
If the door or door seals are damaged, the oven must not be
operated until it has been repaired by a competent person;
It is hazardous for anyone, other than a qualified service
technician, to carry out any service for repairing operation
which involves removal of any cover which gives protection