background image

WMBP

 Series

Brazed Plate Heat

Exchangers

 636-000-042/0109

PRODUCT INFORMATION - APPLICATIONS

INSTALLATION - MAINTENANCE GUIDE

Before proceeding with installation and operation, read entire manual carefully. 

Failure to do so can cause injury, death or substantial property damage.

WMBP heat exchangers are not compatible with steam applications nor ammonia 

(NH3). Such misuses of the product could result in severe personal injury, death or 

substantial property damage.

When receiving WMBP’s, any claims for damage or shortage in shipment must be 

filed immediately against the transportation company by the consignee.

Summary of Contents for WMBP Series

Page 1: ...Failure to do so can cause injury death or substantial property damage WMBP heat exchangers are not compatible with steam applications nor ammonia NH3 Such misuses of the product could result in sever...

Page 2: ...d Indicates special instructions on installation operation or maintenance that are important but not related to personal injury hazards Read all instructions before installing Failure to follow all in...

Page 3: ...o create contact points between all the plates When these points are vacuum brazed together a compact and pressure resistant heat exchanger is formed in which virtually all material is utilized for he...

Page 4: ...313 0 09xN 50 0 16 50 2 64 0 13xN WMBP 4 4 66 12 81 11 06 2 88 0 313 0 09xN 100 0 32 50 3 52 0 26xN WMBP 5 4 66 20 38 18 81 2 88 0 313 0 09xN 100 0 53 50 4 40 0 53xN WMBP 7 10 34 20 63 18 13 7 88 0 31...

Page 5: ...eat Exchanger Design Data Computerized Sizing 636 000 042 0109 5 With our computer program we will select the optimum heat exchanger for your particular applications Please fax this selection sheet ba...

Page 6: ...20 225 000 23 2 8 8 22 7 7 0 Model Btu Hr Supplied Boiler Side 180 F In 160 F Out Snow Melt Side 30 Glycol 100 F In 130 F Out Flow Rate GPM Pressure Drop PSI Flow Rate GPM Pressure Drop PSI WMBP1 14E...

Page 7: ...1 140 102 WMBP1 14E 80 000 3 3 0 9 1 8 0 2 146 108 WMBP1 14E 90 000 3 7 1 2 2 0 0 2 158 120 WMBP1 14E 100 000 4 2 1 4 2 2 0 2 170 132 WMBP1 14E 110 000 4 6 1 8 2 4 0 3 182 144 WMBP1 14E 120 000 5 0 2...

Page 8: ...on Figure 2 For heating applications the plate heat exchanger can be installed in any position The primary side is iden tified by a red label Figure 3 Typical Heating Application Connect the piping in...

Page 9: ...the two exchangers Vent the Air During Filling Vent the heat exchanger s during filling to eliminate any trapped air to assure proper performance and longevity of the heat exchanger Shutting Down the...

Page 10: ...TGVWTP GCVKPI UWRRN QKNGT 9 2 JGCV GZEJCPIGT Heating return Heating supply Hot water Cold Water Boiler WMBP heat exchanger 636 000 042 0109 10 Figure 7 Typical Instantaneous Domestic Water Heating App...

Page 11: ...on and pH A turbulent flow and lower temperature may help reduce the deposit Particles Solids in suspension in the heat transfer media Such a fouling can be influenced by velocity and media flow rough...

Page 12: ...tc psig F F gpm 1000 x Btu hr JOB ENGINEER CONTRACTOR Date Submitted by Approved by 12 636 000 042 0109 WMBP Brazed Plate Heat Exchangers consist of as many as 150 pattern embossed stainless steel pla...

Reviews: