background image

14

SPARE PARTS LIST

No.

CODE

F5

 DESC

R

IPTION

No.

CODE

            

F5

 DES

C

RIPTION

1

     

 

                  

C

8111227    

BURNER BACK COVER

2

3006992

PIPE CONNECTOR - SUPPLY

3

3006571

3/8” NPT/METRIC ADAPTER - MALE

4

3006993

PIPE CONNECTOR - RETURN

5

3005847

1/4” NPT/ METRIC ADAPTER - FEMALE

6

3007077

CRUSHABLE METAL WASHER

7

3007568

BLEEDER

8

3007028

O-RING - PUMP PRESSURE REGULATOR

9

3007202

REGULATOR SCREW

10

3007162

C7010002

O-RING - PUMP COVER

11

3005719

PUMP SCREEN

12

3006925

VALVE STEM

13

3007203

VALVE STEM PLATE

14

3007029

O-RING - VALVE STEM UPPER

15

3007156

O-RING - VALVE STEM LOWER

16

3007268

NOZZLE OUTLET FITTING

17

3007087

CRUSHABLE METAL WASHER 5/8” ID

18

3001157

C7001029

PRIMARY CONTROL 530SE/C

19

3002278

PRIMARY CONTROL SUB BASE

20

3006553

COIL U-BRACKET AND KNURLED NUT

21

3002279

COIL

22

3007802

PUMP

23

3000443

PUMP DRIVE KEY

24

3005843

MOTOR

25

3007316

AIR TUBE COVER

26

3002280

PHOTOCELL

27

3005854

SEMI FLANGE (2 REQUIRED)

29

3020248

MOUNTING GASKET

30

3005708

FAN

31

3005844

CAPACITOR 12.5 µF

32

3007320

ACOUSTIC LINER

33

3007204

MANUAL AIR SHUTTER

34

3020249

ELECTRONIC AIR SHUTTER

35

C7001082

F5 REPLACEMENT AIR DAMPER KIT

OPTIONAL

60

C7001085

TYPE L 24V SWITCHING RELAY

61

C7001033

AMULET - CERAFELT SLEEVE KIT

3007943

CAPILLARY PORT PLUG

Summary of Contents for UltraOil 800057000-Brn-PO Rie F5

Page 1: ...ation descriptions and diagrams for the proper installation and wiring of the burner Please read carefully before attempting final installation This manual is to remain with the final installation des...

Page 2: ...d be thoroughly cleaned prior to installing a new filter cartridge DRAFT Follow the instructions furnished with the heating appliance The pressure in the combustion area should be kept as close to zer...

Page 3: ...ge 5 Method 2 Semi flange Collar 5 Method 3 Pedestal Mount 5 AMULET INSTALLATION INSTRUCTIONS 6 INTERNAL FACTORY WIRING 7 APPLICATION FIELD WIRING 8 NOZZLE PLACEMENT 9 INSERTION REMOVAL OF DRAWER ASSE...

Page 4: ...f the year of manu facture A BI week of manufacture 8511111 Burner product code 00025 Increment of 1 for each burner pro duced specific to product code reset to zero each January 1st Quantity Descript...

Page 5: ...O 530 SE C Ignition transformer 8kV 16mA Model A B C D E F F3 Inches 8 15 32 9 59 64 6 15 32 3 1 2 6 8 29 32 mm 215 252 164 89 152 226 F5 Inches 9 11 64 10 11 16 7 3 32 3 1 2 6 9 13 32 mm 233 272 180...

Page 6: ...screw 2 Carefully pull the DRAWER ASSEMBLY out of the AIR TUBE install the required nozzle see page 8 and set aside C Remove the two BOLTS 3 from FRONT PLATE 4 of the BURNER CHASSIS Align the two hole...

Page 7: ...heating unit is suggested Dimension B should be at least see drawing NOTE A suggested method for creating mounting bolt holes in the mounting gasket Hold the gasket against the appliance mounting bol...

Page 8: ...y onto the tube remove a small amount of the inner diameter with a sharp knife to provide the necessary clearance The diagram below shows the proper position of the amulet after installation D7285 Amu...

Page 9: ...control lock out alarm terminal AUX costant 120V auxiliary terminal electronic air shutter RIELLO 40 F3 F5 SERIES OIL BURNERS EQUIPPED WITH AN ELECTRONIC AIR SHUTTER INTERNAL FACTORY WIRING ATTENTION...

Page 10: ...ner chassis 6 Burner control remote lock out alarm device wired supplied by others AUX Auxiliary bub base add on connector air shutter T T 24V thermostat connections low voltage operated system MIN WI...

Page 11: ...p C Remove the AIR TUBE COVER PLATE 5 by loosening the re taining SCREW 4 Two SCREWS Model F5 D Loosen SCREW 2 and then slide the complete drawer assem bly out of the combustion head as shown E To ins...

Page 12: ...damage the pump body Riello manometers and vacuum gauges do not require any adapters and can be safely connected to the pump ports An NPT metric adapter must be used when connecting other gauge models...

Page 13: ...nto a bucket 4 Loosen the screw s securing the air tube cover allowing it to be re moved freely 5 Holding the air tube cover in its proper location start the burner 6 When the solenoid valve is engage...

Page 14: ...er motor will not operate un til the air shutter is in its fully open position Set the air plate 4 setting according to OEM setup informa tion or by following the Retrofit settings listed in this manu...

Page 15: ...A B139 or NFPA 31 BURNER START UP CYCLE NOTE The above set up charts are a starting point only The burner and appliance must be properly set up using proper combustion testing equipment Normal Lock ou...

Page 16: ...13 EXPLODED SPARE PARTS LIST 35...

Page 17: ...3007268 NOZZLE OUTLET FITTING 17 3007087 CRUSHABLE METAL WASHER 5 8 ID 18 3001157 C7001029 PRIMARY CONTROL 530SE C 19 3002278 PRIMARY CONTROL SUB BASE 20 3006553 COIL U BRACKET AND KNURLED NUT 21 300...

Page 18: ...6977 TURBULATOR DISC 42 3006966 ELECTRODE SUPPORT 43 3006965 NOZZLE ADAPTER 44 3008627 NOZZLE OIL TUBE 44 3008629 NOZZLE OIL TUBE 45 3008633 REGULATOR ASSEMBLY 45 3008634 REGULATOR ASSEMBLY 46 3008630...

Page 19: ...zzle info Pump pressure Turbolator setting Draft overfire Draft breech Air setting CO2 CO O2 Smoke density Bacharach Single line Two lines Burner Start up Info OIL This form was designed and provided...

Page 20: ...474 3556 35 Pond Park Road Hingham MA 02043 Phone 781 749 8292 Toll Free 800 992 7637 Fax 781 740 2069 www riellousa com 2165 Meadowpine Blvd Mississauga ON L5N 6H6 Phone 905 542 0303 Toll Free 800 3...

Reviews: