CONDENSING GAS BOILER

70/110/155

 

If the information in this manual is not followed exactly, a fi re or explosion may result, 

causing property damage, personal injury or loss of life.

Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS —

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any telephone in your building.

•  Immediately call your gas supplier from a neighbor’s telephone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fi re department.
Installation & service must be performed by a qualifi ed installer, service technician or the gas supplier.

Summary of Contents for Evergreen 110

Page 1: ...or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any te...

Page 2: ...onal injury death or substantial property damage Indicates presence of hazards that can cause severe personal injury death or substantial property damage Indicates presence of hazards that will or can...

Page 3: ...cal supply before performing maintenance To avoid severe burns allow boiler to cool before performing maintenance You must maintain the boiler as outlined in the manual and have the boiler started up...

Page 4: ...dirt Areas likely to have contaminants Dry cleaning laundry areas and establishments Swimming pools Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body s...

Page 5: ...Check air openings Check pressure temperature gauge Verify boiler jacket door is securely closed MONTHLY Check vent piping Check air piping Check relief valve Check condensate drain system Check autom...

Page 6: ...auge 1 Make sure the pressure reading on the boiler pressure temperaturegaugedoesnotexceed 24 psig Higher pressure may indicate a problem with the expansion tank 2 Contact a qualified service technici...

Page 7: ...e tube is in good condition and that condensate can run freely 2 Inspect the boiler condensate trap located under the boiler see Figure 3 Make sure the ball float in the trap is in place and appears t...

Page 8: ...n system to refer to after checking relief valve 3 Lift the relief valve top lever slightly allow ing water to relieve through the valve and discharge piping 4 If water flows freely release the lever...

Page 9: ...Part number 550 100 192 0917 9 Figure 5 Operating instructions see page 2 for location of manual gas valve gas fired water boiler 70 110 155 User s information Manual OPERATING INSTRUCTIONS...

Page 10: ...ate also flashes fault name during lockout Active system type Outdoor air temperature Setpoint temperature or percentage if shadow Boiler out or system sensor depending upon settings Firing Rate Input...

Page 11: ...M A N D 1 2 3 N E X T EVG 001 bs 2 H H M M A M M M D D Y Y S T A T U S O U T D O O R T E M P F T A R G E T T E M P F B O I L E R T E M P F M O D U L A T I O N I N P U T S T A T U S 0 1 0 V 1 D H W S...

Page 12: ...12 gas fired water boiler 70 110 155 User s information Manual...