Part number 550-100-260/0520
85
ECO
®
Tec
G
AS
-
FIRED
WATER
BOILER
–
80/110/150/199
B
OILER
M
ANUAL
3YSTEM4YPE
8-Character
Abbreviation
3-Character
Abbreviation
Max
Target
Temp
°F
DHW
Target
°F
OD
Reset
Min °F
Min
Target
Temp
°F
OD
Reset
Max °F
Run
Boiler
Pump
Run AUX
PUMP/
OUTPUT
Fan-coil
FAN-COIL
FCL
180
N/A
0
140
70
YES
YES
Finned Tube Baseboard
FIN BASE
FTB
180
N/A
0
130
70
YES
YES
Cast Iron Baseboard
IRONBASE
CIB
180
N/A
0
120
70
YES
YES
Cast Iron Radiators
RADIATOR
CIR
180
N/A
0
120
70
YES
YES
Radiant - slab on grade
RAD SLAB
RSG
120
N/A
0
80
70
YES
YES
Radiant - thin slab
RAD SLAB
RTS
140
N/A
0
80
70
YES
YES
Radiant - below floor
(staple up)
RADFLOOR
RSU
160
N/A
0
90
70
YES
YES
Radiant - above floor
(sleeper system)
RADFLOOR
RAF
140
N/A
0
90
70
YES
YES
Domestic Hot Water
DOMESTIC
DHW
180
N/A
N/A
N/A
N/A
YES
NO
Combi DHW
COMBI
DHW
N/A
120
N/A
N/A
N/A
YES
NO
Custom (user defined)
XXXXXXXX
(user input)
first three of
user input
180
N/A
0
70
70
YES
YES
options
Default
setting
COMBI
default
UNITS
$
ECO BOOST OFF DIFF &'*"+
1 - 30
N/A
10
°F
$
!*"!
YES, NO
Yes
Yes
-
$
!!!!
YES, NO
No
No
-
$
!
OFF, 1 - 240
OFF
OFF
S
$
POST PUMP
10
30
OFF
S
$
!
11 - 100
100
100
%
$
!
10 - 99
10
10
%
$
ADDITIONAL HEAT DEMAND
ACT CONTACT
OFF, 1ST, 2ND,
Outdoor Temperature
OFF
OFF
-
$
OFF, 1 - 240
OFF
OFF
M
$
TEMP DEPENDENT
YES, NO
NO
N/A
-
$
!
0 - 50
15
N/A
°F
$
ACT CONTACT BELOW SETPOINT
1st, 2nd
1st
N/A
-
Available control settings and system presets
&IGURE
ECO
Tec
Control / Priority settings
(continued)
&IGURE
System Type Presets (each option shown with factory settings)