Check boiler area

  To prevent potential of severe per-

sonal injury, death or substantial 

property damage, eliminate all 

materials discussed below from 

the boiler vicinity. If contaminants 

are found:

 

Remove products immediately 

from the area. If they have been 

there for an extended period, call 

a qualified service technician to 

inspect the boiler and vent system 

for possible damage from acid cor-

rosion.

 

If products cannot be removed, 

immediately call a qualified service 

technician to address the problem.

1.  Combustible/flammable materials — Do not 

store combustible materials, gasoline or any 

other flammable vapors or liquids near the 

boiler. Remove immediately if found.

2.  Air contaminants — Products containing 

chlorine or fluorine, if allowed to con-

taminate the boiler intake air, will cause 

acidic condensate in the vent and boiler.  

This will cause significant damage to the 

vent and/or boiler if allowed to continue.

3.  Read the list of potential materials listed 

on page 4 of this manual. If any of these 

products are in the room from which the 

boiler takes its combustion air, they must be 

removed immediately or the boiler combus-

tion air must be supplied from outside. 

4.  See WARNING above.

Check air openings

1.  Verify that combustion and ventilation air 

openings to the boiler room and/or building 

are open and unobstructed.

2.  Verify that boiler vent discharge and air 

intake are clean and free of obstructions. 

Remove any debris on the air intake or flue 

exhaust openings.

Check boiler pressure/

temperature gauge

1.  Make sure the pressure reading on the boiler 

pressure/temperature gauge does not exceed 

24 psig. Higher pressure may indicate a 

problem with the expansion tank.

2.  Contact a qualified service technician if 

problem persists.

Verify that boiler jacket 

door is securely closed

Visually inspect boiler jacket door to be sure it 

is sealed all around its perimeter. Verify that the 

door latches are secure.

  The boiler jacket door must be 

securely fastened to the boiler 

to prevent boiler from drawing 

air from inside the boiler room. 

Latches should be secure.

 

This is particularly important if the 

boiler is located in the same room 

as other appliances. 

 

Failure to keep the door securely 

fastened could result in severe 

personal injury or death. 

 

Contact your installer or techni-

cian immediately if the front 

door does not close correctly or 

if the door gaskets are damaged.

  The boiler should be inspected and started annually, at the beginning of the heating 

season, only by a qualified service technician. In addition, the maintenance and care of 

the boiler designated on page 5 and explained on the following pages must be performed 

to assure maximum boiler efficiency and reliability. Failure to service and maintain the 

boiler and system could result in equipment failure, causing possible severe personal 

injury, death or substantial property damage.

  The following information provides detailed instructions for completing the mainte-

nance items listed in the maintenance schedule, page 5. In addition to this maintenance, 

the boiler must be serviced and started up at the beginning of each heating season by 

a qualified service technician.

User maintenance procedures

Summary of Contents for Eco Tec 110

Page 1: ...se gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department...

Page 2: ... you can t avoid 4 Maintain boiler Set up a plan for maintaining the boiler using the schedule included in this manual Schedule an annual start up by a qualified service technician before every heating season 5 Start or Shutdown boiler Follow the Operating instruction sheet details to start or shutdown your boiler 9 Understand control display This page shows display screen modes and menu access in...

Page 3: ...emove it The boiler should attempt to restart within an hour If blockage is not obvious or cannot be removed have the boiler and system checked by a qualified service technician Combustion air DO NOT obstruct the combustion air intake or expose the air intake to corrosive chemicals see next page Carbon monoxide detector A carbon monoxide detector that is wired on the same electrical circuit as the...

Page 4: ...or chlorine compounds When these chemicals pass through the boiler they can form strong acids in the vent system or boiler The acid can eat through the vent or boiler wall causing serious damage and presenting a possible threat of flue gas spillage into the building Please read the information on this page If the boiler combustion air inlet is located in any area likely to cause contamination or i...

Page 5: ...ing Check air piping Check relief valve Verify that domestic hot water is being supplied to fixtures at the correct temperature Check condensate drain system Check automatic air vents if used Check display date and time EVERY 6 MONTHS Check boiler piping gas and water Operate relief valve Follow the service and maintenance procedures given throughout this manual and in component literature shipped...

Page 6: ...tions Remove any debris on the air intake or flue exhaust openings Check boiler pressure temperature gauge 1 Make sure the pressure reading on the boiler pressure temperature gauge does not exceed 24 psig Higher pressure may indicate a problem with the expansion tank 2 Contact a qualified service technician if problem persists Verify that boiler jacket door is securely closed Visually inspect boil...

Page 7: ...r Models only Inspect the Domestic Hot Relief Valve and relief valve discharge pipe for signs of weeping or leakage If signs are present contact your qualified service technician Check the condensate drain system 1 Visually inspect the condensate drain tubing and the end of the tube Make sure the tube is in good condition and that condensate can run freely 2 Inspect the boiler condensate trap loca...

Page 8: ... valve continues to weep afterwards contact your qualified service technician to inspect the valve and system 5 If water does not flow from the valve when you lift the lever completely the valve or discharge line may be blocked Immediately shutdown the boiler following the lighting instructions on the inside jacket top Call your qualified service technician to inspect the boiler and system Toavoid...

Page 9: ...Part number 550 100 261 0520 9 OPERATING INSTRUCTIONS ECO Tec Gas fired water boiler 80 110 150 199 User s Information Manual Figure 5 Operating instructions see page 2 for location of manual gas valve ...

Page 10: ...hows the current sequence of operation status with the active priority 0 10v Shows the current 0 10v input value from external device 1 4 Shows inputs 1 through 4 what they are assigned to their custom names and their status Pumps Aux Shows which aux pump outputs are currently active Additional Heat Demand Shows whether AHD is off or on Only appears if a priority is selected to use AHD Outdoor Tem...

Page 11: ...ou will be able to reset it to clear the reminder Figure 8 ECO Tec boiler control display USER Menu set date and time reset faults Figure 9 ECO Tec boiler control display LOCKOUT SCREEN screen turns red when boiler locks out highlight and select MANUAL RESET to reset boiler as shown below Figure 10 ECO Tec boiler control display Maintenance notice screens Date Time Allows user to edit the current ...

Page 12: ...sig on the Combi Domestic Outlet pipe ECO Tec Gas fired water boiler 80 110 150 199 User s Information Manual Figure 11 ECO Tec boiler control display Homeowner Combi controls The ECO Tec control display MENU Item DESCRIPTION The homeowner hot water screen can be accessed by going to the main user menu and selecting the Combi option Hot Water Temp Set target temperature to the required Combi water...

Reviews: