![WEIGHSOUTH WS 10 User Manual Download Page 17](http://html1.mh-extra.com/html/weighsouth/ws-10/ws-10_user-manual_952480017.webp)
4. Maintenance
4.1 Regular error and solution
Wireless
Comm.
C35
C35=0~99 signal
Gravity of
Calibration
Location
C36
C36=9.7000~9.9999
Gravity of Des-
tination
C37
C37=9.7000~9.9999
Version No.
C38
Preserved
Menu
C39
ERROR
REASON
SOLUTION
UUUUUU
1. Overload
2. Wrong connection
with load cell
3. Load cell has quality
issue.
1. Reduce the weight
2. Check load cell connection
3. Inspect load cell. Check the input
and output
nnnnnnn
1. Calibration is off
2. Wrong connection
3. Load cell has quality
issue
1. Check scale feet to see if they are
level
2. Check load cell connection.
3. Checking load cell: check input
and output resistance
ERR1
During calibration, not
input the weights or the
weight is overload
Input the correct weights