Operating
2635530000/00/10.2018
29
click-sound can be heard and the pump handle can be pushed through
easily. Now both dies should lie completely on top of each other.
6
In order to open the dies turn the pump handle (see Figure 1 on page 24)
into the return position (<=||=>).Therefore, the pump handle needs to be
turned left bei 20°. In this position the pump handle is entirely closed. This
process activates the oil reflux. Additionally, the piston moves in its start
position.
7
Because of a fault the piston can move backwards at any time.
8
Remove the cable lug/connector. For this purpose open the crimp head if
necessary.
Whenever several crimpings are necessary start crimping from the flange to
the end of the sleeve (see Figure 3 on page 29). You find the minimum
amount of crimpings in the current Weidmüller crimping-instructions.
When processing connectors, the mentioned number of crimpings has to be
dedicated to each side of the connector.
Figure 3
Working direction for crimpings