Weidmüller 2682430000 Hardware Installation Manual Download Page 2

 

 

 

6                        V1.2 / 2022-03-29 

Refer to illustration below for correct wiring. 

 

Behavior of fault alarm relay (can be triggered by configurable events power failure or 
port link down):  

  Relay contact is closed if the device is powered-off. 

  Relay contact is open if the device is powered-on and no alarm conditions exist (neither 

Power Failure Alarms nor Port Link Loss Alarms are activated (Web menu Warnings 

 

Fault Relay Alarm). 

  Relay contact closes if any of an activated alarm condition happens. 

9.  Communication Connections 

Switch 

IE-SW-AL06M-4GTPoE-2GESFP 

is equipped with the following communication 

interfaces: 
 

4 x 10/100/1000BASE-T(X) PoE ports (P.S.E.)  

 

2 x 100/1000BASE-X Ports (SFP Slots) 

9.1 

10/100/1000BASE-T(X) PoE ports (P.S.E) 

For communication without PoE sourcing the switch supports auto negotiation speed, 
Full/Half duplex mode and auto MDI/MDI-X connection, means automatic setting of pinouts 
for both MDI ports (NIC-type) or MDI-X ports (HUB/Switch-type). 

In case of active PoE sourcing the switch uses the pinout of “

Alternative A, MDI mode

” of 

802.3af/802.3at standards. Please see the details in the following table. 

Pinouts 

10/100/1000BASE-T(X) PoE ports (P.S.E)

 

8-Pin RJ45 

Port 

10/100 BASE-T(X) MDI/MDI-X 

1000BASE-T MDI/MDI-X 

Pin 
No. 

MDI port 

MDI-X port 

Pin 
No. 

MDI port 

MDI-X port 

  

TD+(transmit) with 

PoE Power + 

RD+(receive) 

BI_DA+ with 

PoE Power + 

BI_DB+ 

TD-(transmit) with 

PoE Power + 

RD-(receive) 

BI_DA- with 

PoE Power + 

BI_DB- 

RD+(receive) with 

PoE Power - 

TD+(transmit) 

BI_DB+ with 
PoE Power - 

BI_DA+ 

Not used 

Not used 

BI_DC+ 

BI_DD+ 

Not used 

Not used 

BI_DC- 

BI_DD- 

RD-(receive) with 

PoE Power - 

TD-(transmit) 

BI_DB- with 

PoE Power - 

BI_DA- 

Not used 

Not used 

BI_DD+ 

BI_DC+ 

Not used 

Not used 

BI_DD- 

BI_DC- 

9.2 

100/1000BASE-X SFP fiber optic port 

The 100/1000BASE SFP type slots require either a 100BASE SFP or a 1000BASE SFP fiber 
transceiver (mini-GBIC) to work properly. Please only use SFP modules and cables that are 
compatible with each other to establish an optical connection. 

 
LC-Port Pinouts: 

 

LC-Port to LC-Port Cable Wiring:

 

 

 
 
 
 
 
 
 

For  a  LC-Port  with  separate  Transmit  and  Receive  Port  please  remember  to  connect  the  Tx 
(transmit)  port  of  Device-1  to  the  Rx  (receive)  port  of  Device-2,  and  the  Rx  (receive)  port  of 
Device-1 to the Tx (transmit) port of Device-2. 

9.3 

RS232 Console Port  

The RS232 Interface with RJ45 connector can be used to access the switch console for 
configuration. Additionally, it can be applied with external Backup/Restore module IE-EBR-
MODULE-RS232-ALM (Article no. 2682610000). 
 
Pinouts Serial  
Console Port: 
 
 
 

 

10.  User Management  

10.1  Device Access (Login to Web Interface) 

The Web interface of the Switch can be accessed via following factory default settings: 

IP address / Netmask: 

192.168.1.110 / 255.255.255.0

 

User name: 

admin

 

Password: 

Detmold

 

Connect the PC to any Ethernet port of the managed Switch and set the PC’s IP address to a 
free one of range 192.168.1.0 / 255.255.255.0 

Start a web browser and enter the IP address of the connected Switch into the browser’s 
address line (http://192.168.1.110). After the appearance of prompt (login) enter the login 
credentials. After confirmation of your input with "OK" the home page of the switch will be 
displayed. 

10.2  Reset Button (Behavior of Factory Default Settings) 

  Pressing < 5 seconds: Reboot the switch (Warm Start) and sets IP to 

Factory Default IP. 

  Pressing >= 5 seconds: Resets the switch configuration to Factory Default Settings. 

Note: Behavior of reset button can be configured in the Web Interface (Menu Factory Default). 

11.  LED Indicators 

The front panel of the Ethernet Switch contains several LED indicators. The function of each 
LED is described in the table below. 

LED 

Color 

Status 

Description 

PWR1 

Green 

On 

Power is supplied to power input PWR1. 

PWR2 

Green 

On 

Power is supplied to power input PWR2. 

R-MSTR 
(Ring Master) 

Green 

On 

Is Ring Master of an enabled O-Ring. 

Ring 

Green 

On 

O-Ring redundancy is enabled. 

Blinking 

Ring structure is broken (No redundancy). 

PoE 

Green 

On 

Power supplied over Ethernet 

LNK/ACT 
(Ports G1-G4) 

Green 

On 

Port link is active. 

Off 

Port link is inactive. 

Blinking 

Data is transmitted. 

10/100/1000M 
(Ports G1-G4) 

Green / 

Amber 

Green 

Port speed is set to 1000 Mbps. 

Amber 

Port speed is set to 100 Mbps. 

Off 

Port speed is set to 10 Mbps. 

LNK/ACT 
(SFP Ports 
G5-G6) 

Green 

On 

Port link is active. 

OFF 

Port link is inactive. 

Blinking 

Data is transmitted. 

FAULT 

Amber 

On 

Fault Relay indication for Power failure and Port link loss. 

12.  Disposal Information 

 

Observe the notes for proper disposal of the 
product. You can find the notes here: 

www.weidmueller.com/disposal

  

 

13.  Specifications 

Technology 

Ethernet Standards  

IEEE 802.3 for 10BASE-T 
IEEE 802.3u for 100BASE-TX and 100BASE-FX 
IEEE 802.3ab for 1000BASE-T 
IEEE 802.3z for 1000BaseX 
IEEE 802.3x for flow control 
IEEE 802.3af/at for Power over Ethernet  
IEEE 802.3ad for port trunk with LACP 
IEEE 802.1D for STP (Spanning Tree protocol) 
IEEE 802.1w for RSTP (Rapid Spanning Tree protocol) 
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol) 
IEEE 802.1p for Class of Service 
IEEE 802.1Q for VLAN Tagging 
IEEE 802.1x for Authentication 
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol) 

Processing Type 

Store and Forward 

MAC Table size 

8K 

Packet buffer size 

4 Mbit 

Backplane bandwidth 

12 Gbps 

Jumbo frame support 

Up to 9.6 kBytes 

Interfaces 

RJ45 Ports 

10/100/1000BASE-T(X) PoE ports (P.S.E.) compliant to PoE 
standard IEEE 802.3af/at 

Fiber optic ports 

2 x 100/1000BASE-X SFP slots 

RS232 Console Port 

RS232 Interface with RJ45 connector for Console access and 
useable with external Backup/Restore module 

LED Indicators 

PWR1, PWR2 (Power), Fault (Relay), Ring Master, Ring 
Status, Port Link/Activity/Speed, PoE 

Relay Contact 

Max. 1A @ 24 V DC for Power Failure and Port Link Loss 

Power 

Input Voltage 

12/24/48 V DC (12 - 57 V DC), 2 redundant inputs 

Input Current  
(with PD consumption)

 

6.6 A @ 12 V DC; 5.68 A @ 24 V DC; 2.76 A @ 48 V DC

 

Connection 

One removable 6-pin terminal block, Wiring cable 12-24AWG 

Overload Current Protect. 

Present 

Reverse Polarity Protect. 

Present 

PoE

 

Total power budget

 

60 W @ 12 – <24 V DC; 120 W @ 24 - 57 V DC 

PoE Pinout

 

Mode A: Pin 1, 2 (V+); Pin 3, 6 (V-); Alternative A; MDI

 

Physical Characteristics 

Housing 

IP30 protection, metal  

Dimension (W x H x D) 

54.3 x 145.1 x 108.5 mm (2.14 x 5.71 x 4.27 inch) 

Weight  

678 g 

Installation 

DIN-rail 

Environmental conditions 

Operating Temperature 

-40 to 75°C (-40 to 167°F) 

Storage Temperature 

-40 to 85°C (-40 to 185°F) 

Ambient Relative Humidity 

5 to 95% (non-condensing) 

Operating Altitude 

Up to 2000 m 

Regulatory Approvals 

Safety 

UL 61010-1; UL 61010-2-201 

EMC 

EN 55032, EN 55024, FCC Part 15 Subpart B Class A,  
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,  
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,  
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,  
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,  
IEC 61000-4-6 CS: 3 V 

Shock 

IEC 60068-2-27 

Free Fall 

IEC 60068-2-31 

Vibration 

IEC 60068-2-6 

MTBF

 

Time 

495.624 hrs 

Database 

Telcordia SR332 

Warranty 

Time Period 

5 years 

Contact Information 

 

Weidmüller Interface GmbH & Co. KG 

Klingenbergstraße 26, 32758 Detmold / Germany 

Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083 

E-Mail 

[email protected]

,  Internet 

www.weidmueller.com 