![Weidmüller 1253240000 Manual Download Page 18](http://html1.mh-extra.com/html/weidmuller/1253240000/1253240000_manual_952350018.webp)
Setup and Network Configuration
18
1253240000/00/02.11
Figure 12
Transferring the firmware file with FTP
Use the command “ftp
IP-address
” to establish the FTP-connection to the repeater and confirm the user log-
in with
Enter
. The confirmation “
user logged in
” appears.
With the command “put
filename
” you can transfer the new firmware to the device.
Note
The transfer of the firmware needs only a few seconds, then follows a check and
the update of
the repeater, which needs up to 2 minutes.
During this update process only the LEDs US1
and US2 glow. Never interrupt the power supply during the firmware update process. After the
successful update the repeater will start automatically and is again reachable via the old IP-
address.
The GSDML-file, witch is located on the repeater, will also be updated with the firmware update process.
Check after installation whether the file is actual
Detailed description of the firmware update you will find at