2 Safety

 | General safety notice

4

2484950000/00/03.2016

Manual UR67-PROIFBUS

2  Safety

This section includes general safety instructions for handling 

the u-remote IP67 modules. Specific safety instructions for 

specific tasks and situations are given at the appropriate 

places in the documentation. 

Work on the u-remote products may only 

be performed by qualified electricians that 

are familiar with the safety standards in au-

tomation technology. 
The documentation should be stored in a 

way that it is accessible for the personnel 

at any time.

2.1  General safety notice

When working during continued operations, the emergency 

stop mechanisms must not be made ineffective.

If a malfunction on a u-remote product cannot be fixed after 

following the recommended measures (see Chapter 9), the 

product in question must be sent back to Weidmüller. Wei-

dmüller does not assume any liability if the base or electronic 

module has been tampered with! 

All connected devices have to fulfill the requirements of 

EN 61558-2-4 and EN 61558-2-6. Only lines and accesso

-

ries may be installed that fulfill the requirements and rules 

für safety, electromagnetic compatibility and telecommuni-

cation devices as well as the specifications. All information 

about approved lines and accessories are provided in this 

manual or available from Weidmüller.

Electrostatic discharge

u-remote products can be damaged or destroyed by electro-

static discharge. When handling the products, the necessary 

safety measures against electrostatic discharge (ESD) ac-

cording to IEC 61340-5-1 and IEC 61340-5-2 must be ob

-

served. The packing and unpacking as well as the installation 

and di sassembly of a device may only be carried out by quali-

fied personnel and in accordance with the ESD information.

Fusing

The operator must set up the equipment so that it is protect-

ed against overloading. The upstream fuse must be designed 

such that it does not exceed the maximum load current. The 

maximum permissible load current of the u-remote compo-

nents can be found in the technical data.

The operator has to decide whether additional overvoltage 

protection according to IEC 62305 is required. Voltages that 

/-30 V may cause the destruction of the modules. A 

power supply with protective separation has to be used for 

power feed-in.

Earthing (functional earth FE) 

Each IP67 remote-I/O module is provided with an earthing 

connection. On the metall modules the connection point is 

indicated as „XE“. When using the modules made from plas-

tics the earthing clamp has to be connected. 

Further information are provided in Chapter 6 „Earthing and 

shielding“.

Shielding 

Shielded lines are to be connected with shielded plugs in 

compliance with the relevant standard (see Chapter 6).

2.2  Intended use

The UR67 PROFIBUS-I/O modules are intended for use as de

-

centralised input and output devices within a PROFIBUS-DP 

network in industrial automation. The products may only be 

used within the described technical specification.

The devices to be connected must fulfill the requirements ac

-

cording to EN 61558-2-4 and EN 61558-2-6. 

The industrial environment is characterised by the fact that 

appliances are not connected directly with the public low 

voltage system. Special measurements have to be taken for 

the use in residential areas, business or trade areas.

Any intervention in the products hard or software other than 

described in this manual may only be realised by Weidmüller.

Undisturbed operation is only be guaranteed with the hous-

ings completely closed. The observance of the documenta-

tion is part of the intended use.

2.3  Legal notice

The u-remote IP67 series products are CE-compliant in ac-

cordance with Directive 2014/30/EU (EMC Directive).
Components of the following free software products are inte-

grated into the u-remote products:

Component

Licence

Link

Ecos

modified GPL http://ecos.sourceware.org/license-overview.html

Summary of Contents for UR67-PB-12-8DI-8-30K

Page 1: ...426340000 UR67 PB 78 8DIDO 12 60M 2426380000 UR67 PB 78 16DI 12 60M 2426390000 UR67 PB 78 16DO 12 60M 2426400000 UR67 PB 12 8DI 8 30K 2426360000 UR67 PB 12 8DIO 8 30K 2426330000 Remote I O System u re...

Page 2: ...Preparations for assembly 27 5 2 Assembling the module and earthing connection 27 5 3 Attaching the markers 31 5 4 Adjusting the PROFIBUS address 31 5 5 Wiring 31 5 6 Insulation test 31 6 Earthing an...

Page 3: ...otes with the signal word Attention warn you of hazards which may result in material damage Text next to this arrow are notes which are not relevant to safety but provide important infor mation about...

Page 4: ...overloading The upstream fuse must be designed such that it does not exceed the maximum load current The maximum permissible load current of the u remote compo nents can be found in the technical dat...

Page 5: ...UR67 PB 78 16DI 12 60M 16 digital outputs UR67 PB 78 16DO 12 60M The output current is up to 1 6 A per channel The output circuits are galvanically isolated from either the rest of the network and fr...

Page 6: ...Power Out SAI SK M12 UNI 2330260000 M12 Bus In Power In SAI SK plug M12 1781520000 Markers Module and connection markers are available as accessories for the purpose of item designation All markers c...

Page 7: ...reverse polaritiy protection Protect the actuator supply with a overcurrent protect tion 6 A mT that will release at least 10 100 ms after a short circuit Diagnosis and status LED LED Indicator Meani...

Page 8: ...24 V DC 25 3 internally bridged GND GND 4 GND 5 FE FE ATTENTION Product can be destroyed Please do never position the power supply 24 V DC at the signal or data lines pin 1 to pin 4 PROFIBUS DP M12 5...

Page 9: ...uring the next switch on of the power supply Changing the address Set the new address as described above Interrupt the power supply temporarily The new address set will be adopted during the next swit...

Page 10: ...e Type 3 acc to IEC 61131 2 Rated input voltage 24 V DC Input current at 24 V DC typ 5 mA Short circuit proof yes Status indicator LED yellow channel wise Diagnosis indicator LED red channel wise Port...

Page 11: ...2 5 pole Supply of actuators Rated voltage UL 24 V DC Voltage range 24 V DC 25 Potential isolation yes Low voltage threshold typ 17 V Low voltage detection delay 20 ms Reverse polarity protection yes...

Page 12: ...itiy protection Protect the actuator supply with a overcurrent protect tion 6 A mT that will release at least 10 100 ms after a short circuit Diagnosis and status LED LED Indicator Meaning UL green Ac...

Page 13: ...V DC 25 5 n c 24 V DC 25 The internal T piece is connected through 5 pole even with the UR67 PB 78 16DI 12 60K module ATTENTION Product can be destroyed Please do never position the power supply 24 V...

Page 14: ...orarily The new address set will be adopted during the next switch on of the power supply Setting the address via the network Prior to this you have to set the rotary switches to 00 This setting may n...

Page 15: ...es Status indicator LED yellow channel wise Diagnosis indicator LED green per socket Connection M12 5 pole A coded Outputs Number of digital channels max 16 configurable Channel type NO contact p swit...

Page 16: ...tion yes Low voltage threshold typ 17 V Low voltage detection delay 20 ms Reverse polarity protection yes Actuator supply indicator UL LED green Connection 7 8 5 pole General data Protection class IP...

Page 17: ...a fail safe func tion For these modules the behaviour of each output in case of communication failure or interruption can be configured UR67 PB 78 8DIDO 12 60M I O module with 8 digital inputs and 8 d...

Page 18: ...it off Not connected status off no error LED indicators error messages see chapter 9 Connection assignments I O connections M12 A coded 8DIDO 16DI 16DO 1 3 5 4 2 1 X1 X4 24 V X5 X8 n c 24 V n c 2 X1 X...

Page 19: ...6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 BUS Rotary switches on the module Set the address with the rotary switches hundred left decade middle unit posit...

Page 20: ...A coded Outputs Number of digital channels 8 16 Channel type NO contact p switching NO contact p switching Output current typ 1 6 A acc IEC 61131 2 typ 1 6 A acc IEC 61131 2 Rated output current per c...

Page 21: ...yes yes Low voltage threshold typ 17 V typ 17 V Low voltage detection delay typ 300 ms typ 300 ms Reverse polarity protection yes yes Actuator supply indicator UL LED green red LED green red Connecti...

Page 22: ...This parameter defines the status of the outputs after a com munication interruption or failure within the PROFINET IO network The following settings are possible Set low The output channel will be di...

Page 23: ...6DO 12 60M Bit 7 6 5 4 3 2 1 0 Input data Byte n 4B 4A 3B 3A 2B 2A 1B 1A 1A 8A Status output channel A Pin 4 of M12 sockets 1 8 Byte n 1 8B 8A 7B 7A 6B 6A 5B 5A 1B 8B Status output channel B Pin 2 of...

Page 24: ...l as soon as the power supply UL has normalised Error of system sensor supply US The voltage values of the system sensor supply connections US are monitored overall An error will be reported as soon a...

Page 25: ...ber 0 15 Channel no 0 socket 1 channel A Channel no 1 socket 1 channel B usw Channel no 15 socket 8 channel B Byte 12 Channel type Bit 001 Error type Only error type 1 is used Indicating a diagnosis i...

Page 26: ...e failure has been resolved 1 The Bit is always 1 if the DP slave with this PROFIBUS address is present 1 The access monitoring is enabled with this DP slave 1 The DP slave has received the control co...

Page 27: ...ed by electrostatic discharge Please make sure that personnel and work equipment are adequately earthed Unpack all parts Dispose of all packaging in accordance with the local dis posal guidelines The...

Page 28: ...DIA 8 US L U UR67 PB 12 8DIO 8 30K x1 x10 x10 x1 x10 x1 IN OUT BUS AUX IN 28 4 40 4 19 23 6 30 12 205 4 197 188 M4x40 1 Nm M4x40 1 Nm M12 PROFIBUS DP M12 M8 M4x30 35 1 Nm M4x30 35 1 Nm 5 0 1 2 3 4 9 8...

Page 29: ...IA 5 6 2 A DIA B 3 A DIA B 7 8 A DIA B 4 U U S L UR67 PB 78 16DI 12 60K PROFIBUS 16DI Max Ambient Temp 10 60 C 14 140 F 5 0 1 2 3 4 9 8 7 6 5 0 1 2 3 4 9 8 7 6 39 5 13 13 33 39 243 233 233 60 30 5 M4x...

Page 30: ...V 1 2 3 4 Pin Power Function M12 I O Function Pin 1 2 3 4 5 24V In B GND 0V In A Earth 1 2 3 5 4 female 5 1 2 4 5 3 1 2 3 5 4 n c housing earth VP 5V Line A DGND 0V Line B 1 2 3 4 5 Pin Function AUX X...

Page 31: ...he place of installation has been disconnected from the power supply Once the module has been mechanically installed the wiring can be carried out in accordance with the wiring plan Ensure compliance...

Page 32: ...n return as short as possible and using twisted pair wire Far better protection however is provided by completely shielding of all cables This is the most effective measure that can be taken against t...

Page 33: ...a separate earth When installing ground connections on shielding it is gen erally also important that no earth loops are created The smaller the earth loop the less the danger of the induction of inte...

Page 34: ...st be ob served during installation of the u remote modules Proper extensive earthing of inactive metal parts Correct shielding of cables and equipment Proper layout of wires cabling Creation of a uni...

Page 35: ...cabinet housing 4 Busbar The busbar must be connected via the rail holding fixture The cable shields are fixed to the busbar 5 Protective earth conductor rail The protective earth conductor rail must...

Page 36: ...to have a one sided shield connection for reasons specific to the circuit or equipment the second side of the cable shield can be routed to the local reference potential via a capacitor with short co...

Page 37: ...Metal housing zinc diecast completely potted 60 mm wide C UR67 PB 78 8DIDO 12 60M UR67 PB 78 16DI 12 60M UR67 PB 78 16DO 12 60M WIUR0E94 GSD If bitmap files for visualising the modules are also suppl...

Page 38: ...he station SIMATIC 300 is displayed below in the directory tree Click on the station SIMATIC 300 Double click Hardware on the right hand side of the window The Hardware Configuration window opens Hard...

Page 39: ...spective version or use the mouse to drag it to the second position in the table on the left hand side of the window The Properties Ethernet interface window opens Ethernet interface properties Enter...

Page 40: ...I O UR67 system open the module line from which you want to add a module e g UR67 PB 78 XXX 12 60M Choosing the module Double click on the designated module line or drag it exactly to the subnet line...

Page 41: ...elete or Using the right mouse button click on the module in the list and select Delete Setting module parameters A wide range of parameters can be edited for some modules Navigate to the list of comp...

Page 42: ...ectronic equipment Make sure that disassembled products are properly disposed of When all u remote products reach the end of their life cycle you can return them to Weidm ller and we will arrange for...

Page 43: ...Yellow Channel A On Red Peripheral error actuator low voltage sensor or actuator short circuit Off Not connected status Off no error Red Check the connected periphery for short circuit check the power...

Page 44: ...pply Red Check the power supply of the module UL Green Actuator supply OK Red Actuator supply 18 V or 30 V Off No actuator supply Red Check the power supply of the module ACT Yellow Data exchange with...

Page 45: ...ir industries and markets and know the technological challenges of tomorrow We are therefore continuously developing innovative sustainable and useful solutions for their individual needs Together we...

Reviews: