background image

 

Wiring Requirements 

 

WARNING 

Turn the power off before disconnecting modules or wires. 
The correct power supply voltage is listed on the product 
label. Check the voltage of your power source to make sure 
that you are using the correct voltage. Do NOT use a 
voltage greater than what is specified on the product label. 

These devices must be supplied by a SELV source as 
defined in the Low Voltage Directive 2006/95/EC and 
2004/108/EC. 

 

 

ATTENTION 

Safety First! 

Be sure to disconnect the power cord before installing 
and/or wiring your Weidmüller switch. 

This device has UL508 approval. Use copper conductors 
only, 60/75°C, Tighten To 4.5 pound-inches. For use in 
Pollution Degree 2 Environment. 

 

 

ATTENTION 

Safety First! 

Calculate the maximum possible current in each power wire 
and common wire. Observe all electrical codes dictating the 
maximum current allowable for each wire size. If the current 
goes above the maximum ratings, the wiring could 
overheat, causing serious damage to your equipment. 

 

You should also heed the following guidelines: 

  Use separate paths to route wiring for power and devices. If power 

wiring and device wiring paths must cross, make sure the wires are 
perpendicular at the intersection point.  

NOTE: Do not run signal or communications wiring and power 
wiring in the same wire conduit. To avoid interference, wires 
with different signal characteristics should be routed 
separately. 

  You can use the type of signal transmitted through a wire to 

determine which wires should be kept separate. The rule of thumb is 
that wiring that shares similar electrical characteristics can be 
bundled together. 

  Keep input wiring and output wiring separated. 

  It is strongly advised that you label wiring to all devices in the system 

when necessary. 

 
 
 
 

Summary of Contents for IE-SW-IP67-5M12

Page 1: ...roduct information can be downloaded using following link http www weidmueller com Select Product Catalogue Select Industrial Ethernet active Select IP67 unmanaged Switches Select Product model Click...

Page 2: ...Class 1 Division 2 and comply with CE FCC and UL standards Package Checklist Your Ethernet Switch is shipped with the following items If any of these items is missing or damaged please contact your We...

Page 3: ...ed M12 socket with D coding 3 Port Label 4 Power input 5 pin male shielded M12 socket with A coding 5 Power input PWR LED 6 Device Type 7 Holes for attaching the IE SW IP67 T 5M12 to a wall with screw...

Page 4: ...3 screw holes on the wall based on the positions of the 3 screw holes on the switch shown in the mounting dimensions diagram STEP 2 Insert one screw in the top middle screw hole on the switch and scre...

Page 5: ...nd common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to...

Page 6: ...T X Ethernet ports 4 pin shielded M12 socket with D coding The 10 100BaseTX ports located on the front panel are used to connect to Ethernet enabled devices Most users configure these ports for Auto M...

Page 7: ...D Power input Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Input V Not assigned Input V Not assigned Function ground Pinouts for RJ45 8 pin RJ45 8 Pin MDI Port Pinouts MDI X Port Pinouts Pin Signal 1 Tx 2 Tx 3 Rx 6...

Page 8: ...8 M12 4 pin M to M12 4 pin M Straight Trough Cable Wiring M12 4 pin M to RJ45 8 pin Cross Over Cable Wiring M12 4 pin M to RJ45 8 pin Straight Trough Cable Wiring...

Page 9: ...the IE SW IP67 T 5M12 to Ethernet devices Dual Speed Functionality Switching The IE SW IP67 T 5M12 10 100 Mbps switched M12 ports auto negotiate with the connected device to use the fastest data tran...

Page 10: ...for speeds in the 10BaseT and 100BaseTX modes with operation according to the IEEE 802 3u standard This means that some nodes could be operating at 10 Mbps while at the same time other nodes are opera...

Page 11: ...verload Current Protection 1 1 A Reverse Polarity Protection Present Physical Characteristics Housing Plastic IP67 protection Dimensions 60 x 125 x 29 6 mm W x H x D Weight 250 g Installation Panel Wa...

Page 12: ...otherwise in writing in this catalogue product description Weidm ller gives no warranty or guarantee as to the interoperability in specific systems or as to the fitness for any particular purpose To t...

Reviews: