background image

12 

 

 

ATTENTION 

To actively update DIP switch settings, power off and then 
power on the Ethernet Switch. 

 

LED Indicators 

The front panel of the Ethernet Switch contains several LED indicators. 
The function of each LED is described in the following table. 

LED 

Color 

State 

Description 

PWR1 

AMBER 

On 

Power is being supplied to power 
input P1. 

Off 

Power is not being supplied to 
power input P1. 

PWR2 

AMBER 

On 

Power is being supplied to power 
input P2. 

Off 

Power is not being supplied to 
power input P2. 

10/100M 

AMBER 

On 

TP port’s 10 Mbps link is active.

 

Blinking 

Data is being transmitted at 10 
Mbps.

 

Off 

TP Port’s 10 Mbps link is inactive.

 

GREE

On 

TP port’s 100 Mbps link is active.

 

Blinking 

Data is being transmitted at 100 
Mbps.

 

Off 

TP Port’s 100 Mbps link is inactive.

 

100M 

GREEN 

On 

FX port’s 100 Mbps link is active. 

Blinking 

Data is being transmitted at 100 
Mbps. 

Off 

FX Port’s 100 Mbps link is inactive. 

PoE+ 

AMBER 

On 

Power is being supplied to Powered 
Device (PD) 

Off 

Power is not being supplied to 
Powered Device (PD) 

 

Auto MDI/MDI-X Connection 

The Auto MDI/MDI-X function allows users to connect the Ethernet 
Switch 10/100BaseTX ports to any kind of Ethernet device, without 
needing to pay attention to the type of Ethernet cable being used for the 
connection. This means that you can use either a straight-through cable 
or cross-over cable to connect the Ethernet Switch to Ethernet devices. 

 
 

Summary of Contents for IE-SW-BL06-1TX-4PoE-1SC

Page 1: ...product information can be downloaded using following link http www weidmueller com Select Product Catalogue Select Industrial Ethernet active Select PoE unmanaged Switches Select Product model Click...

Page 2: ...be easily installed on a DIN Rail or in distribution boxes The DIN Rail mounting capability and IP30 metal housing with LED indicators make the switch reliable and easy to use Package Checklist Your...

Page 3: ...ew 2 Terminal block for power input P1 P2 3 Heat dissipation orifices 4 DIP switches 5 Power input P1 LED 6 Power input P2 LED 7 PoE LED 8 10 100BaseT X port 9 TP port s 10 100 Mbps LED 10 Article Num...

Page 4: ...E 1ST Front Panel View 1 Grounding screw 2 Terminal block for power input P1 P2 3 Heat dissipation orifices 4 DIP switches 5 Power input P1 LED 6 Power input P2 LED 7 PoE LED 8 10 100BaseT X port 9 TP...

Page 5: ...ont Panel View 1 Grounding screw 2 Terminal block for power input P1 P2 3 Heat dissipation orifices 4 DIP switches 5 Power input P1 LED 6 Power input P2 LED 7 PoE LED 8 10 100BaseT X port 9 TP port s...

Page 6: ...f you need to reattach the DIN Rail attachment plate make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN Rail into the slot just...

Page 7: ...he screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right NOTE Before tightening the screws into the wall make sure the...

Page 8: ...ice wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interfere...

Page 9: ...hernet Switch top panel ATTENTION Before connecting the Ethernet Switch to the DC power inputs make sure the DC power source voltage is stable Communication Connections The IE SW BL06 series has 4 5 o...

Page 10: ...the polarity of the power supply and shall be able to operate per MDI mode and MDI X mode However some PDs only support MDI mode or MDI X mode only The following figure shows how to select the correct...

Page 11: ...t of device I to the Tx transmit port of device II SC Port Pinouts ST Port Pinouts ATTENTION This is a Class 1 Laser LED product To avoid causing serious damage to your eyes do not stare directly into...

Page 12: ...f TP Port s 10 Mbps link is inactive GREE N On TP port s 100 Mbps link is active Blinking Data is being transmitted at 100 Mbps Off TP Port s 100 Mbps link is inactive 100M GREEN On FX port s 100 Mbps...

Page 13: ...suitable for use with large networks The address tables are self learning so that as nodes are added or removed or moved from one segment to another the Ethernet Switch automatically keeps up with new...

Page 14: ...ode Wavelength 1300 nm Max TX 10 dBm Min TX 20 dBm RX Sensitivity 32 dBm Link Budget 12 dB Typical Distance 5 km a 4 km b Saturation 6 dBm a using 50 125 m 800 MHz km cable b using 62 5 125 m 500 MHz...

Page 15: ...40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level...

Page 16: ...n Weidm ller gives no warranty or guarantee as to the interoperability in specific systems or as to the fitness for any particular purpose To the extent permitted by law any claims for damages and rei...

Reviews: