Summary of Contents for BOX WM4 C

Page 1: ...Montageanleitung PV Feldsteckverbinder WM4 C Gehäusesteckverbinder BOX WM4 C Installation instructions PV Field connector WM4 C PV Box connector BOX WM4 C ...

Page 2: ...rface GmbH Co KG Klingenbergstraße 16 D 32758 Detmold T 49 5231 14 0 F 49 5231 14 292083 www weidmueller com Inhalt Verwendete Symbole 2 Allgemeine Sicherheitshinweise 3 Sicherheitshinweise für die Montage 3 Bestimmungsgemäßer Gebrauch 3 Empfohlendes Werkzeug 3 Steckverbinder montieren 4 Steckverbinder öffnen 7 Technische Daten 8 Bestelldaten 9 Content Symbols used 10 General safety notes 11 Safet...

Page 3: ...te nicht mit WM4 Gehäusen kombiniert werden und umgekehrt Stellen Sie sicher dass spannungsführende Teile wie Kontakte oder Kabel keinen Erdschluss erzeugen Wenn Sie andere Komponenten Hilfsmittel oder Werk zeuge als die von Weidmüller angegebenen bei der Mon tage einsetzen kann die Einhaltung der technischen Spe zifikationen nicht garantiert werden Die PV Steckverbinder dürfen keinen mechanischen...

Page 4: ...Benötigtes Werkzeug Crimpwerkzeug PV 1222870000 Beachten Sie die Anleitung zum Werkzeug Stellen Sie den Positionsgeber auf WM4 ein Legen Sie den Metallkontakt entsprechend dem Kabel querschnitt in die passende Öffnung des Handwerkzeugs ein Führen Sie das Kabel in den Crimpbereich und betätigen Sie die Crimpzange vollständig Achten Sie darauf dass am Crimp keine Beschädigungen und scharfen Kanten e...

Page 5: ...m Klick verrastet Bei Kabeln mit dem maximalen Außendurchmesser von 7 mm kann es notwendig sein die Überwurf mutter zurückzudrehen Prüfen Sie die korrekte Verrastung durch einen leichten Zug am Kabel Schritt 4 WM4 C Gehäuse montieren Benötigte Werkzeuge Screwty SW15 1290830000 DMS MANUELL 0 5 1 7 9918370000 Drehen Sie die Überwurfmutter per Hand an Ziehen Sie die Überwurfmutter mit dem Werkzeug fe...

Page 6: ...ngen vor Wenn Sie einen Rotations schutz erreichen wollen beachten Sie die linke Bohr skizze Achten Sie darauf dass die Bohrung gratfrei ist be vor Sie mit der Montage fortfahren Benötigte Werkzeuge Screwty SW18 1254670000 DMS MANUELL 0 5 1 7 9918370000 Montieren Sie den Steckverbinder mit der Dichtung auf der Außenseite der Wand und der Mutter auf der Innen seite Ziehen Sie die Mutter mit dem Wer...

Page 7: ...ch leichtes Ziehen Steckverbinder öffnen WARNUNG Gefährliche Spannung Je nach Lichteinstrahlung kann vom Modul erzeugte Spannung anliegen Die elektrischen Verbindungen dürfen nicht unter Last gesteckt und getrennt wer den Die Gehäuseteile des Steckverbinders können ohne Werk zeug getrennt werden Um den Steckverbinder zu öffnen drücken Sie die Rast haken zusammen und ziehen Sie die Gehäuseteile aus...

Page 8: ...hutzklasse II Bauart einpoliger nicht wiederverwendbarer freier Steckverbinder Anzugsdrehmoment 5 5 6 0 mm 2 0 Nm 0 2 6 0 7 0 mm 1 5 Nm 0 2 1 1 0 2 Nm Max Wandstärke Metallgehäuse 6 mm Kunststoffgehäuse 10 mm Anschließbare Kabel Kabel nach Standard 2 PfG1169 08 2007 und EN 50618 2014 flexible Leitungen Litze verzinnt Kabelquerschnitt 4 mm2 6 mm2 Kabelaußendurchmesser 5 5 7 0 mm Isolierstoffgruppe ...

Page 9: ...C RL Stiftkontakt 100 1500 1530680000 1530780000 Zubehör Typ VPE Best Nr VSSO WM4 C Staubschutzkappe universell für Buchsen und Stiftgehäuse 100 1254870000 Verpackungseinheit BOX WM4 C Gehäusesteckverbinder Buchsen gehäuse Typ VPE Best Nr BUGH BOX WM4 C BT Buchsengehäuse 100 1530630000 BUKO WM4 C BT BUKO WM4 C RL Buchsenkontakt 100 1500 1530670000 1530770000 Stiftgehäuse Typ VPE Best Nr SFGH BOX W...

Page 10: ...connectors 12 Disconnecting the plug 15 Technical data 16 Order data 17 Symbols used This symbol cautions against danger caused by hazardous voltage This symbol cautions against danger that may re sult in material damage This symbol advises you to regard this and other documentations if applicable The arrow indicates notes that enable proper and effective work procedures ...

Page 11: ...ke sure during installation that WM4 C contacts will not be combined with WM4 housings and vice versa Make sure that energized parts like contacts or cables will not induce a ground fault We can not guarantee the technical specifications if you use other components accessories or tools for installa tion than recommended by Weidmüller The PV plug in connectors must not be subjected to any mechanica...

Page 12: ... individual strands of the cable Step 2 Crimping the contacts Required tool Crimping tool PV 1222870000 Please regard the tool s documentation Set the locator to WM4 Put the metal contact into the appropriate cavity of the manual tool according to the cable cross section The locator helps you to position the contact properly Insert the cable into the crimp area and press the crimp ing pliers compl...

Page 13: ...ing cables with the maximum external diameter of 7 mm it may be neccessary to turn back the un ion nut Check that the fastening is correct by gently pulling the cable Step 4 WM4 C Assembling the housing Required tools Screwty SW15 1290830000 DMS MANUELL 0 5 1 7 9918370000 Tighten the union nut manually Fasten the union nut using the tool When doing so please observe the appropriate tightening torq...

Page 14: ...the adjacent drawings If you want to achieve the anti rotation protec tion please regard the left hand drawing Please make sure that the opening is free of burrs before you continue the assembly Required tools Screwty SW18 1254670000 DMS MANUELL 0 5 1 7 9918370000 Mount the connector with the sealing on the outer part of the wall and the nut on the inner part of the wall Tighten the nut using the ...

Page 15: ...tening is correct by gently pulling Disconnecting the plug WARNING Hazardous voltage The electrical connections must not be discon nected and plugged under load Depending on the light intensity voltage generated by the module may be present The housings of the plug can be separated without any tool To disconnect the connector press the latching hooks together and pull the housing components apart ...

Page 16: ... class II Construction type unipolar not reuseable free connector Tightening torque 5 5 6 0 mm 2 0 Nm 0 2 6 0 7 0 mm 1 5 Nm 0 2 1 1 0 2 Nm Max wall thickness Metall enclosure 6 mm Plastic enclosure 10 mm Connectable cables Cable according to standard 2 PfG 1169 08 2007 and EN 50618 2014 flexible lines strand tinned Cable cross section 4 mm2 6 mm2 Cable exterior diameter 5 5 7 0 mm Insulating mater...

Page 17: ... pin contact 100 1500 1530680000 1530780000 Accessories Type Pack unit Order No VSSO WM4 C Universal dust cap for female socket housing and male pin housing 100 1254870000 Packaging unit BOX WM4 C Box connector Female socket housing Type Pack unit Order No BUGH BOX WM4 C BT Female socket housing 100 1530630000 BUKO WM4 C BT BUKO WM4 C RL Female socket contact 100 1500 1530670000 1530770000 Male pi...

Page 18: ...Weidmüller Interface GmbH Co KG Klingenbergstraße 16 D 32758 Detmold T 49 5231 14 0 F 49 5231 14 292083 www weidmueller com 2454640000 02 07 2017 ...