9�2
Maintenance intervals
Î
Inspect the WEH
®
Product at regular intervals depending on the respective oper-
ating conditions, but at least every 3 months. After 20,000 cycles or 3 years at the
latest, depending on what happens first, starting from the date of delivery (invoice/
goods issue date by WEH or the distributor), the WEH
®
Product must be sent to
WEH for maintenance.
These intervals can also be significantly shorter, which depends especially on your
individual application/use. Therefore, in case of abnormalities – especially during
regular inspection – send the WEH
®
Product immediately to WEH for maintenance.
If the WEH
®
Product is not regularly inspected and sent to WEH for maintenance,
leakage may occur and under certain circumstances this may result in failures and/
or accidents.
9�3
Overview of minimum intervals for inspection and maintenance
No�
Connector
Inspection
Initial
(before com-
missioning for
the 1st time)
Weekly
1
all TW156
Check exterior for damage and dirt
X
X
2
all TW156
Check clamping jaws for correct
functioning and any damage
X
X
3
all TW156
Check connector and media line for
)
X
X
4
TW156H
Check function and ease of move-
ment of the hand lever
X
X
5
TW156V
Check the tightening torque of the
grub screw
X
X
No�
Connector
Maintenance
Monthly
After 3 years or
20,000 cycles*
6
TW156H
Lubricate hand lever
(
X
7
all TW156
Return to WEH for in-factory
maintenance
X
* depending on what happens first
Note:
For component arrangement see
Chapter 3. Product overview / product descrip-
.
Î
If your application requires, set shorter intervals thanindicated above. A significant
shortening of the minimum intervals is particularly necessary if abnormalities are
found during the inspections.