ETHERNET

RJ45 Jack

1

TXDO +

2

TXDO  -

3

RXDI  +

4

Shorted together, then terminated into an AC ground.

5

6

RXDI  -

7

Shorted together, then terminated into an AC ground.

SERIAL CONTROL

RS232, 9 pin D female jacks

1

DCD (internally pulled to +5V)

2

RxD (data output)

3

TxD (data input)

4

DTR (not connected)

5

GND

6

DSR (internally pulled to +5V)

7

RTS (internally pulled to +5V,may be upgraded for 
handshaking)

8

CTS (not used presently, may be upgraded for 
handshaking)

9

RI (internally pulled to +5V, with weak current limiting)

ALARM/ CUEING

10-pin male header (mates to 
removable terminal strip)

1

OK (COM closes here when OK)

2

COM:

3

Alarm (COM closes here on alarm or if power is off)

4

GND

5

Cue Relay #1:  N.C. contact

6

Cue Relay #1:  Common contact

7

Cue Relay #1:  N.O. contact

8

Cue Relay #2:  N.C. contact

9

Cue Relay #2:  Common contact

10

Cue Relay #2:  N.O. contact

DTMF*

3-pin male header (mates to 
removable terminal strip)

1

DTMF tone, non-inverted output

2

GND

3

Alarm (COM closes here on alarm or if power is off)

AUDIO (same for both 

ports 1 and 2)

6-pin male header (mates to 
removable terminal strip)

1

Right '+'

2

Right GND

3

Right '-'

4

Left '+'

5

Left GND

6

Left '-'

COMPOSITE VIDEO OUT

BNC Jack

Composite Video Output

ASI OUT

BNC Jack

DVB-ASI Output

Connector Designation

Type

Pin

Signal Description

Summary of Contents for UNITY 4600

Page 1: ...x containing the unit should include Carefully unpack the items and inspect for obvious signs of physical damage that might have occurred during shipment Any damage claims must be reported to the carr...

Page 2: ...ption does not exceed the limits of the AC branch circuit Appropriate consideration of equipment ratings should be used when addressing this concern Reliable Earthing Reliable earthing of rack mounted...

Page 3: ...rear panel views for the Unity 4600 connections DTMF is not available for units manufactured after 10 22 2007 Figure 2 Unity 4600 rear panel with DTMF Figure 3 Unity 4600 rear panel without DTMF Table...

Page 4: ...g ALARM CUEING 10 pin male header mates to removable terminal strip 1 OK COM closes here when OK 2 COM 3 Alarm COM closes here on alarm or if power is off 4 GND 5 Cue Relay 1 N C contact 6 Cue Relay 1...

Page 5: ...indicating RF signal level 0 to 100 where 100 is max power and 0 is min Eb No if locked on a carrier or others indicating unit state or the presence of faults Note that the flashing arrow at the lowe...

Page 6: ...nt One or more warning indications present usually indicates a problem with the incoming signal a minor unit fault a possible impending failure or that important information is available Off No warnin...

Page 7: ...obligation under this warranty is limited to repairing or at Wegener Communications option replacing parts subassemblies or entire assemblies Wegener Communications shall not be liable for any specia...

Reviews: