DANGER 

Reliable Earthing 

Reliable earthing of rack-mounted equipment should be maintained. Particular attention should 
be given to supply connections other than direct connections to the branch circuit (use of power 
strips, chassis ground lugs, etc.). 

 
Lithium Battery 

Proper disposal and replacement of the motherboard’s lithium battery is necessary. Replacing the 
battery with an incorrect type presents the risk of explosion. Dispose of used batteries according 
to the package instructions. 

 
Telecommunication Line Cord 

To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. 

 
Rack Installation Procedure 

The iPump i6420 is sized at 1 RU and will fit an EIA-standard, 19-inch-wide equipment rack. 

1)  Install angle brackets or cross-supports capable of supporting both the unit and its 

connecting cables. Screw or bolt the supports securely to the equipment rack. 

2)  Place the iPump 6420 on its supports and use four anchor screws or bolts and nuts to 

secure the unit's front brackets to the rack. 

 
WARNING 

Do not block any of the ventilation or fan opening on the front, side, or rear of the unit. Support 
arrangements that do not allow adequate air flow or that block the openings on front, side and 
rear vents may result in overheating and damage to the iPump 6420. 

 
WARNING 

The front brackets must be secured to the rack. If front brackets are left unsecured, the unit may 
shift forward and fall from the rack during installation or operation. Failure to secure the front 
brackets may result in personal injury and/or damage to the equipment. 

 
WARNING 

Locate the iPump 6420 and its cables to avoid impacts, spills, and pulling cables and to ensure 
sufficient air flow. Failure to locate the iPump 6420 in a proper environment may result in damage 
to the equipment.

 

 