Reading Parameters
15-2 | CFW300
15
P006 - Inverter Status
Adjustable
Range:
According to
Factory
Setting:
Properties:
ro
Description:
It indicates one of the possible inverter status. The following table contains the description of each state, as well
as the indication on the HMI.
Table 15.1:
Inverter status- P006
P006
Status
HMI
Description
0
Ready
Indicates the inverter is ready to be enabled
1
Run
Indicates the inverter is enabled
2
Sub
Indicates the voltage in the inverter is too low for operation
(undervoltage), and will not accept the enabling command
3
Fault
Indicates the inverter is in the fault status. The fault code
will flash
4
Self-tuning
Indicates the inverter is executing the Self-Tuning routine
5
Configuration
Indicates the inverter has incompatible parameter
programming. After pressing the key
, it will keep
showing an arrow until the incorrect setting is corrected, as
shown in the figure. Refer to
7
Reserved
-
-
8
Fire Mode
Indicates that the inverter is in Fire Mode. After pressing
the
key, letter "A" will continue to flash indicating the
state. See
Section 9.3 ENERGY SAVING on page 9-7
P007 - Output Voltage
Adjustable
Range:
0 to 240 V
Factory
Setting:
Properties:
ro
Description:
It indicates the line voltage in inverter output, in Volts (V).
Summary of Contents for CFW300 V1.3X
Page 2: ......
Page 8: ...Contents...
Page 46: ...Identification of the Inverter Model and Accessories 6 4 CFW300 6...
Page 60: ...Logical Command and Speed Reference 7 14 CFW300 7...
Page 72: ...V f Scalar Control 9 10 CFW300 9...
Page 80: ...VVW Vector Control 10 8 CFW300 10...
Page 116: ...Digital and Analog Inputs and Outputs 12 24 CFW300 12...
Page 132: ...Reading Parameters 15 6 CFW300 15...