Using the M600
The M600 control panel gives important feedback on the
status of the M600:
Status
Red
Orange
Green
Ready
Fixed
Fixed
Stand-by
Fixed
Flashing
Boiler active
Fixed
Boiler fault
Fixed
Water tank too hot
Flashing
Level sensor low
Flashing
Boiler overtemp.
Fixed
Flashing
POWER
LIGHT - WHITE
When the generator is on, this light should be illuminated. If
the generator does not start, then the generator plug should
be checked. If the generator breaker position is correct and
the generator does not start the M600 should be checked by
a competent service engineer.
AMBER
HEATER
LIGHT
If the amber light is illuminated the water is below 96
degrees centigrade and is being heated. If the amber light
does not illuminate, and the red fault light stays on, there
may be a system fault (see below)
GREEN
READY
LIGHT
When this light is illuminated the M600 is ready for use. If
the green light is not illuminated the water may need
heating (amber light will be on) or there is a system fault
(red fault light will be on, see below).
FLASHING ORANGE LIGHT
If the amber light is flashing the water in the water tank is
too hot. If water in the water tank exceeds 45°C the boiler
will shut down. The water tank will need to be drained and
refilled with cold water, or the level topped up with cold
water.
BLUE
RESET
LIGHT
The blue reset light should switch off when the reset button
is pressed during start up. If the light stays on there is an
electrical fault which needs rectification. The M600 should
be switched off until the fault has been corrected.
FLASHING BLUE
RESET
LIGHT
A flashing blue reset light indicates a boiler fault. The M600
must be switched off and checked by a competent service
engineer.
RED
FAULT
LIGHT
The red fault light will illuminate at start up until the green
button is pressed and the amber light illuminates. If the red
light stays on, and the amber light fails to illuminate, the
system may need to be bled to remove air (see section 7).
If the red light fails to switch off after bleeding there is a
system fault. The M600 should be switched off until the fault
has been corrected by a competent service engineer.
Summary of Contents for Foamstream M600
Page 1: ...USER MANUAL ENGLISH EU 16 05 2018 ISSUE 3 ...
Page 2: ...M600 User manual English EU 16 05 2018 ISSUE 3 ...
Page 18: ...M600 User manual English EU 16 05 2018 ISSUE 3 18 Figure 15 Running screen of the PLC ...
Page 32: ...M600 User manual English EU 16 05 2018 ISSUE 3 15 Schematics Figure 22 M600 P ID ...