LX3V-2PT2DAI-BD

 

2                                                       

                                                                             

WECON Technology Co., Ltd. 

Table 2-1 

Address 

Description 

Address 

Description 

M8112 

The flag of RTD type in CH1 

OFF: RTD Type is PT100 

ON: 

Disabled 

D8112 

CH1’s temperature at 0.1 

 

units 

M8113 

The flag of RTD type in CH1 

OFF: RTD Type is PT100 

D8113 

CH2’s temperature at 0.1 

 units 

M8114 

CH3: Flag of the input mode 

OFF: Current output mode 

D8114 

Digital value of CH3 

M8115 

CH4: flag of the input mode 

OFF: Current output mode 

D8115 

Digital value of CH4 

 

3.

 

Dimension 

 

 

Figure 3-1 

 

LED lights indicating: 

 

POW LED: Constantly ON when PLC power ON; 

 

COM LED: Lit when communicating PLC, OFF when timeout; 

 

CH1 LED: LED for CH1, constantly ON when analog signal in range, lit when analog signal out of 

range (-100~600 

). OFF when M8112 turns ON. 

 

CH2 LED: LED for CH2, constantly ON when analog signal in range, lit when analog signal out of 

range (-100~600 

). OFF when M8113 turns ON. 

 

CH3 LED: LED for CH3, constantly ON when M8114 turns OFF, OFF when M8114 turns ON. 

 

CH4 LED: LED for CH4, constantly ON when M8115 turns OFF, OFF when M8115 turns ON. 

 

4.

 

Specifications 

 

Table 3-1 

IN-2PT part 2/3-wire PT100 

IN-2DAI Part Input voltage 

ranges: 4~20mA 

L1+  CH1 PT100 signal input (+)  Io3+  CH3 current output (+) 

L1-  CH1 PT100 signal input (-) 

Io3-  CH3 current output (-) 

VI-  Sensor common pole 

▪ 

Disconnect 

L2+  CH2 PT100 signal input (+)  Io4+  CH4 current output (+) 

L2-  CH2 PT100 signal input (-) 

Io4-  CH4 current output (-) 

 

Summary of Contents for LX3V-2PT2DAI-BD

Page 1: ...LX3V 2PT2DAI BD User manual Website http www we con com cn en Technical Support support we con com cn Skype fcwkkj Phone 86 591 87868869 QQ 1043098682 Technical forum http wecon freeforums net...

Page 2: ...in unit of the LX3V can only use one BD board Don t try to use two or more BD boards these BD boards will not work 5 When mounting module to PLC all the lights are blinking after power ON PLC it means...

Page 3: ...ating PLC OFF when timeout CH1 LED LED for CH1 constantly ON when analog signal in range lit when analog signal out of range 100 600 OFF when M8112 turns ON CH2 LED LED for CH2 constantly ON when anal...

Page 4: ...CH1 CH2 Sensor current 1mA sensor 100 PT100 Compensation range 100 600 Digital output 1000 6000 Unit 0 1 12 bits total 11 bits for data and 1 bit for sign Accuracy 0 2 0 3 Overall accuracy 0 5 Convers...

Page 5: ...le from the high voltage cable at lease 100mm 2 The shielding wire cable shall be grounded But their grounding point can be the same with high voltage lines 3 Never connect cable with forbidden size 4...

Page 6: ...2 D8113 in digital form Values will be automatically stored when the END order is sent out The value is calculated by the designated analog data conversion characteristics of the special auxiliary rel...

Page 7: ...ut of the standard specifications Additional programming orders will be needed to multiply or divide the converted value Caution Since the use of additional programming orders the converted precision...

Page 8: ...changes the digital value 0 2000 to analog value 4 20mA If the real digital range is 0 A A means any value it must be converted to 0 2000 as the following program shows the final digital need to be s...

Reviews: