Tapping into the cold water line

(Using the water supply adapter model FW 1)

Drilling the hole for the faucet

1.   For best results, a ½” carbide-tipped drill bit should be used to drill a hole into your sink for the 

      auxiliary faucet.

2.   Carefully select the faucet location making sure it will have a neat water fall pattern and that 

      the faucet stud will be accessible from below once the hole is completed.

3.   For Porcelain Sink: Before starting the drill motor, apply firm downward pressure on the bit until 

      a crunching occurs. This will help keep the drill bit from moving.

4.   For Stainless Steel Sink: Before using a ½” carbide drill bit, an indent should be made with a 

      center punch to keep the drill bit from moving. A small pilot hole will also aid the ½” drill bit.

5.   For best results, keep steady firm pressure during the start of the hole will cause excess wear 

      on the bit and progress will be slow.

6.   Once the hole is complete, clean the area of metal chips and roughness around the hole. 

      Metal chips will stain Porcelain.

4

NOTE: The drinking water system must be connected to the COLD 
water supply only.

1.   Turn off the cold water supply to the sink faucet
      by locating the Round or oblong handle on the 
      right side of the sink cabinet and Turning clockwise 
      until the water supply is off.

NOTE: If the cold water shut-off valve fails to turn off the water, the 
house water  supply can be turned off at the main water supply.

2.   The water supply adapter can be installed at the faucet Connection (A of Fig. #3) of the cold 
      water line or at the shut-off Valve connection (B of Fig. #3).

3.   Disconnect the threaded nut at the connection and thread the water supply adapter, with 
      the flat washer in place, onto the connection and tighten. Connect the white tubing to the 
      water supply adapter with the treaded nut and tighten.

4.   Thread the needle valve into the adapter tightly and turn the handle clockwise all the way in. 
      Turn on cold water supply to the sink faucet and check for leaks.

NOTE: Safety glasses should be worn to protect your eyes while drilling the faucet hole.

INSTALLATION INSTRUCTIONS

NEEDLE VALVE

WATER SUPPLY

ADAPTER

Fig. #3

VGRO Owners Manual

© 2017 Water Engineering Corporation

Summary of Contents for VGRO Series

Page 1: ...VGRO Series Water Engineering Corporation Long Beach CA U S A 1 888 675 5187 sales wecofilters com WECO Reverse Osmosis Drinking Water Filter System Manual www wecofilters com...

Page 2: ...the water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after system System must be installed indoor It is recommended that installation of the water f...

Page 3: ...ct Water Flow Restrictor Check Valve INLET 3nd Stage CARBON PRE FILTER Water supply adapter valve Cold water shut off valve Auxiliary faucet Garbage disposal Carbon Filters Drain Saddle Storage tank w...

Page 4: ...Flow Restrictor Check Valve INLET INLET 3nd Stage CARBON PRE FILTER BRINE IN Water supply adapter valve Cold water shut off valve Auxiliary faucet Garbage disposal Carbon Filters Drain Saddle Storage...

Page 5: ...l chips will stain Porcelain 4 NOTE The drinking water system must be connected to the COLD water supply only 1 Turn off the cold water supply to the sink faucet by locating the Round or oblong handle...

Page 6: ...o sink with the stem going through the hole 2 Place metal washer and lock washer over threaded stem of faucet and tighten nut from under the counter surface to lock the faucet into place DO NOT OVER T...

Page 7: ...ain pipe and tighten the two screws evenly Fig 7 NOTE The center hole on the sponge must be removed 4 Connect the Black tubing to the drain clamp Fig 7 CONNECTING THE SYSTEM Use the color coded tubing...

Page 8: ...aminated water is being rejected by the reverse osmosis membrane 7 START UP PROCEDURE DO NOT DRINK THE WATER FROM THE FIRST TANK PRODUCED BY THE SYSTEM DISCHARGE THE WATER FROM THE STORAGE TANK BY OPE...

Page 9: ...tank Drain the storage tank by lifting the faucet handle into the parallel position with the spigot until water flow stops from the tank Return the faucet handle to the closed position and the tank w...

Page 10: ...tank Drain the storage tank by lifting the faucet handle into the parallel position with the spigot until water flow stops from the tank Return the faucet handle to the closed position and the tank w...

Page 11: ...off the feed water to the system by turning the saddle valve on the water supply adapter clockwise until it stops 2 Close the storage tank ball valve by turning the handle perpendicular to the valve...

Page 12: ...w wecofilters com For questions and concerns please feel free to contact our support staff Phone 1 888 675 5187 Email sales wecofilters com Water Engineering Corporation 1037 Stanley Ave Long Beach CA...

Page 13: ...12 This page is intentionally left blank VGRO Owners Manual 2017 Water Engineering Corporation...

Page 14: ...WECO VGRO Series Reverse Osmosis Drinking Water Filter System Manual Water Engineering Corporation Long Beach CA U S A 1 888 675 5187 sales wecofilters com WECO www wecofilters com...

Reviews: