Cod.006.0001.1840
13/07/2016 v2.2
ENGLISH
Discovery 300 AC/DC
24/34
NO STORED JOB
The message appears only if there are saved JOBS, on the following displays: D2
E1
Use the encoder to select the number of the job to be deleted.
Exit without confirmation
Press any button (except S2).
This action will automatically close the menu.
Exit with confirmation
S2
Press the button.
This action will automatically close the menu.
13
TORCH TRIGGER MODES
13.1
2T LIFT-ARC WELDING
1.
Touch the workpiece with the torch electrode.
2.
Press (1T) and keep the torch trigger pressed.
3.
Slowly lift the torch to strike the arc.
The welding current reaches the preset value, by way of a up slope time, if programmed.
4.
Release (2T) the trigger to start the weld completion procedure.
The current reaches the end current value in the time set in the down slope time parameter.
The arc is extinguished.
Gas delivery continues for the time set in the post gas parameter.
13.2
2T HF WELDING
1.
Bring the torch up to the work until the electrode tip is approximately 2 or 3 mm away.
2.
Press (1T) and keep the torch trigger pressed.
The arc strikes without contact with the workpiece and the voltage discharges (HF) cease automatically.
The welding current reaches the preset value, by way of a up slope time, if programmed.
3.
Release (2T) the trigger to start the weld completion procedure.
The current reaches the end current value in the time set in the down slope time parameter.
The arc is extinguished.
Gas delivery continues for the time set in the post gas parameter.
13.3
4T LIFT-ARC WELDING
1.
Touch the workpiece with the torch electrode.
2.
Press (1T) and release (2T) the torch trigger.
3.
Slowly lift the torch to strike the arc.
The welding current reaches the preset value, by way of a up slope time, if programmed.
4.
Press (3T) the trigger and keep it pressed to start the weld completion procedure.
The current reaches the end current value in the time set in the down slope time parameter.
The arc continues and the current output will be the value set in the end current parameter.
In these conditions the weld pool can be closed (crater filler current).
5.
Release (4T) the trigger to extinguish the arc.
Gas delivery continues for the time set in the post gas parameter.
Summary of Contents for Discovery 300 AC/DC
Page 2: ...Cod 006 0001 1840 13 07 2016 v2 2 ENGLISH Discovery 300 AC DC 2 34...
Page 28: ...Cod 006 0001 1840 13 07 2016 v2 2 ENGLISH Discovery 300 AC DC 28 34 15 SPARE PARTS...
Page 31: ...Discovery 300 AC DC Cod 006 0001 1840 13 07 2016 v2 2 ENGLISH 0 31 34...
Page 33: ...Discovery 300 AC DC Cod 006 0001 1840 13 07 2016 v2 2 ENGLISH 0 33 34...
Page 34: ...Cod 006 0001 1840 13 07 2016 v2 2 ENGLISH Discovery 300 AC DC 34 34...