![Weco Discovery 200 AC/DC Instruction Manual Download Page 14](http://html1.mh-extra.com/html/weco/discovery-200-ac-dc/discovery-200-ac-dc_instruction-manual_949533014.webp)
WELD THE WORLD
Cod. 006.0001.0340
15/04/2021 V.2.13
Discovery 200AC/DC
14
ENGLISH
4 MMA WELDING
STOP
AC
L1
L2
E1
D1
J1
S1
S2
S3
S4
L25
L15
L16
L17
L18
L19
L21
L22
L23
L24
L20
Hz
L12 L13 L14
L3
L6
L4
L5
L7
L8
L9
L10 L11
A
B
SETTING
ACTIVATION
A
○
Press the
S4
button to activate the MMA mode.
STOP
AC
L1
L2
E1
D1
J1
S1
S2
S3
S4
L25
L15
L16
L17
L18
L19
L21
L22
L23
L24
L20
Hz
L12 L13 L14
L3
L6
L4
L5
L7
L8
L9
L10 L11
A
L 20
MMA
B
○
Using the
encoder E1
, edit the value of the selected setting. The value is saved automati
-
cally.
Tab. 2 - Parameters of the 1st level menu: MMA mode
SETTING
MIN
DEFAULT
MAX
WELDING CURRENT
MAXIMUM CURRENT WITH REMOTE CONTROLLER
7 A
80 A
150 A
- WELDING CURRENT
○ This parameter regulates the primary welding current value.
- MAXIMUM CURRENT WITH REMOTE CONTROLLER
○ The maximum output current value that can be achieved with foot pedal controller external refer
-
ence.