PEAK TIME
Time for which the current pulse is at the maximum value.
Consequences of a higher value:
-
Greater weld penetration.
-
Facility to make deeper cuts.
Consequences of a lower value:
-
Reduction of heat-affected zone.
-
Difficult to create a weld pool.
The welding parameters are available in accordance with the selected welding mode and procedure.
The table shows the settings required to enable each parameter.
Tab. 6 - Table showing enabled Welding Parameters
MENU
↓
MODE
→
SYN
PROCEDURE
→
SPOT
SPOT
SPOT
SPOT
PARAMETER
↓
1°
WELDING CURRENT
X
X
X
X
X
X
X
X
X
X
1°
PRE-GAS TIME
X
X
X
X
X
X
1°
STARTING CURRENT
X
X
X
X
X
X
X
X
X
X
1°
SLOPE UP
X
X
X
X
X
X
X
X
X
X
1°
PULSED CURRENT FRE-
QUENCY
X
X
X
X
1°
DOWN SLOPE
X
X
X
X
X
X
X
X
X
X
1°
FINAL CURRENT
X
X
X
X
X
X
X
X
X
X
1°
POST GAS TIME
X
X
X
X
X
X
X
X
X
X
2°
SPOT WELDING TIME
X
X
2°
BASE CURRENT
X
X
X
X
X
2°
PEAK TIME
X
X
X
X
X