WEBTEC DHC 151 Operating Manual Download Page 3

TROUBLE SHOOTING WITH THE HYDRAULIC TESTER

PRELIMINARY:Check oil level in tank, pump drive, valve linkage for damaged parts, external

oil leaks etc

Problem

Possible Cause

Suggested Test,

See Paragraph:

Excessive pump noise

Pump cavitation caused by:

fluctuating pressure

a) Clogged suction filter

3.0; 4.1

b) Restricted suction line

Low flow under no load

c) Air leak in pump suction line,

fittings, shaft seals etc.

d) Pump speed too high

Decreasing performance

Internal leakage in:

as pressure increases

a) Pump

3.0; 4.1

on all circuits

b) Main Relief Valve

4.2; 4.3

On one circuit

c) Directional Control Valve

4.2; 4.3; 4.4; 5.0

d) Cylinder or Hydraulic Motor

5.1; 5.2

Fails to hold load

Directional Control Valve

4.2; 4.3; 4.4; 5.0

Cross line Relief Valve

5.02

Cylinder

5.0; 5.2

2

Summary of Contents for DHC 151

Page 1: ...Simplified Digital Hydraulic Testers Operating Manual Webtec Products Limited Simplified Digital Hydraulic Testers DHC 51 151 DHT 401 751 751 HP www webtec co uk www oilsolutions com au...

Page 2: ...hen the tester block is used for reverse flow tests slightly lower accuracies may be obtained depending on the oil viscosity density and compressibility 3 The tester should be connected to the hydraul...

Page 3: ...tion filter 3 0 4 1 b Restricted suction line Low flow under no load c Air leak in pump suction line fittings shaft seals etc d Pump speed too high Decreasing performance Internal leakage in as pressu...

Page 4: ...gital display The preset units are displayed in either USGPM IGPM or LPM and the selection is indicated by a cursor arrow When the flow rate falls below the minimum allowable L is indicated on the dis...

Page 5: ...DIRECTIONAL INTERNAL SAFETY DISC WEBSTER HYDRATEST DHT ON OFF OPEN LOADING VALVE BEFORE STARTING MACHINE PP3 64F22 6AM6 A1604 BATTERY INTERNAL SAFETY DISC TEMPERATURE FLOW o LPM C oF US IMP GPM F GPM...

Page 6: ...EST UNIT 1 1 Connect the Tester to the circuit see page 22 for Port Sizes The inlet and outlet ports are marked on the turbine block Use hoses and fittings of sufficient diameter for the flow being te...

Page 7: ...on 3 4 Pump flow at rated pressure can now be checked against the pump manufacturer s specifications The decrease in flow from the minimum pressure to maximum pressure determines the pump condition Ty...

Page 8: ...to end of stroke 4 22 Close the Tester loading valve while watching pressure and flow meter reading Pressure will increase until relief valve opens at which point flow reading will return to zero Note...

Page 9: ...tester loading valve and record both pressure and flow 4 43 If the SAME decrease in flow is noted as in test per paragraph 4 332 then the control valve is at fault HOWEVER if the flow readings are no...

Page 10: ...the outlet port of the motor without first checking the allowable back pressure with the manufacturer Motor Leakage 5 22 Measure hydraulic motor r p m with tachometer when motor is working at normal...

Page 11: ...10 Pump Cylinder Motor Directional Valve Relief Valve Test Hose Relief Valve Drawing B2...

Page 12: ...essure Port 201 mm 54 mm 200 mm 167 mm Inlet Outlet 1 1 2 4 Bolt SAE Flange Type Ports 44 5 mm 133 4 mm 270 mm 1 4 Pressure Port 200 mm 192 mm Inlet Outlet 1 1 2 4 Bolt SAE Flange Type Port 226 mm Mod...

Page 13: ...Safety Disc Cartridge 106 mm 16 mm Inlet Outlet Port Adjustable Gauge Cutout Pressure Gauge 50 mm 121 mm Pressure Loading Valve ON OFF TEMPERATURE FLOW o LPM C o F US IMP GPM F GPM a s t OPEN LOADING...

Page 14: ...r DHC 51 151 Testers only 64 mm Inlet Outlet Ports See Specification 108 mm 50 mm 121 mm HV100 Pressure Loading Valve Safety Disc Cartridge Inlet Output Port 106 mm 16 mm FT1475 40 Gauge Cut out Valve...

Page 15: ...solvent Turbine should revolve freely when blown along flow straightener D Ensure the turbine block is also free of debris Replace the turbine assembly ensuring the clipped corner of the flow straight...

Page 16: ...oading valve becomes inoperative and the oil flows freely downstream To replace the discs remove the cartridge assembly by unscrewing the 1 3 8 AF hexagon Unscrew internal holder in cartridge remove t...

Page 17: ...rnally at approximately 7 bar 100psi over the maximum pressure When the discs fail the loading valve becomes inoperative and the oil flows freely downstream To replace the safety discs remove the load...

Page 18: ...ed to rupture internally at approximately 100 psi 7 bar over the maximum pressure When the discs fail the loading valve becomes inoperative and the oil flows freely downstream To replace the safety di...

Page 19: ...to 420 bar 6 000 psi Specification Pressure Gauge 0 420 bar 0 6000 psi 1 12 BSPF PARALLEL 1 1 2 SAE type four bolt flange Solid 350 bar 5000 psi Split 200 bar 3000 psi 1 7 8 UNF Models Working Pressu...