25
9.
Connecting and configuring DIO ports
< ote> Wire Handling
Trimming Wire
When connecting a wire to a terminal block, follow the instructions below. Note the different types of
wire that can be used.
Standard Wire : Peel off the wiring, cover
8~10mm and solder it. Wire gage should be
AWG 22~26.
Solid Wire : Peel off the wiring cover 8~10mm
and solder it. Wire gage should be AWG 20~26
Inserting & removing wire
To insert & remove wirte in TERMINAL BLOCK,
use a screwdriver in the diagram to the right.
9.1.
Connecting and configuring sensor
9.1.1.
Specification
In order to run sensor input of eDVR MD1600L normally, the following conditions are required.
Spec.
Input Ch.
16Ch Photo coupler inputs
Input type
N.C (Normal Close)/ N.O. (Normal Open) type.
Supported sensor
Dry contact sensor
Connecting
Connecting the trimmed wire to terminal block
Performance
Available input pulse range
Min. 500ms
Output current
Typical DC 12mA