Install&User Manual
98
Edition
Select INDEX to edit and change weekday, program,time directly.
In case that INDEX 50 are all configured, select the time zone to change by mouse click and
click the time again, previouse configuartion will be deleted and new configuration will be
shown.
Caution : If selecting the same time twice, “!” will be shown on the chart.
When configuring time sector, previously configured time can not be included.
De-interlace
Set playback deinterlace On/Off.
It works on Full Dq recording. In “On” status, screen vibration of paused Full D1 video will be
redcued.
6.6.2.3
Event recording setup
Select resolution and frame rate and quality for event recording.
There are 4 trigers – Sensor, Motion detection, Text, Digital input.
First, select the program and check resolution and frame rate and quality of the channel.
(refer to 6.6.1, program configuration)
Event recording can syncro manual&event, Scheduel&Event.
Select among Manual&Event, Schedule&Event in “Recording mode” of [Record configuration]-
[recording]
Reference : Please, check below to configure event recording.
1. Select one of Manual&Event, Schedule&Event.
2. In program configuration, set frame rate by 0 fps in general mode and only
configure Event frame rate.