8
3). The minimum size of the ventilation hole (s) should not be less than 1/4
inch.
d). The remote LP cylinder enclosure should be constructed with non-
combustible materials. The remote LP cylinder enclosure should isolate
the LP cylinder from the burner compartment, so that it provides shielding
from radiation, be a fl ame barrier and provide protection from foreign
material such as hot drippings.
e). There should be a minimum of 2 inches (50.8mm) between the ground
and the fl oor of the remote LP cylinder enclosure.
f).
The LP cylinder valve should be readily accessible for hand operation.
A door on the remote LP cylinder enclosure to gain access to the LP
cylinder valve is acceptable, provided it is non-locking and can be opened
without the use of tools.
If your licensed contractor or licensed plumber builds an LP cylinder enclosure
following the guidelines in the ANSI Standard for Outdoor Cooking Gas
Appliances,
Z21.58 CSA 1.6, you need to order kit number (#21287), which will contain the
hose and regulator assembly, mounting bracket for the regulator, connection
fi ttings and LP tank bracket for retaining the LP cylinder that must be used with
the Summit
®
Built-In gas grill. The hose and regulator in the kit (#21287) is
listed as part of the CSA listed Summit
®
Built-In gas grill.
DANGER
Use of any other hose and regulator assembly could be
dangerous, and may not provide adequate gas supply to
the Summit
®
Built-In gas grill, and could result in a fi re
or an explosion causing serious bodily injury or death,
and damage to property.
DANGER
Failure to use the Summit
®
Built-In Tank Cabinet for a
20 lb cylinder or failure to build a LP cylinder enclosure
for a 20 lb cylinder following the requirements for
ventilation, cylinder retention and separation of the LP
cylinder from a heat source, listed in the ANSI Standard
for Outdoor Cooking Gas Appliances, ANSI Z21.58 CSA
1.6, could be dangerous, and could result in a fi re or an
explosion causing serious bodily injury or death and
damage to property.
If you do not follow the DANGER statements exactly, the Warranty on the
Summit
®
Built-In gas grill will be voided.
CONNECT GAS SUPPLY
1)
Uncap the fl are fi tting from the optional side burner connection located
inside the Summit
®
Built-In
Tank Cabinet (#21280).
Note: We strongly recommend that you use the Summit
®
Built-In Tank
Cabinet (#21280) for installations using a 20 lb LP cylinder, mounted
remotely in an “island” structure.
If your, licensed contractor or licensed plumber, builds an LP cylinder
enclosure following the guidelines in the ANSI Standard for Outdoor
Cooking Gas Appliances,
Z21.58 CSA 1.6, you need to order kit number (#21287).
2) Connect the corrugated gas line to the side burner Connection.
90º
fitting
Connection to
LP Tank
Cap
(Optional
Side Burner)
Plug unused hole
with supplied plug.
Side View
back of
box
top of
box
90º
fitting
Connection to
LP Tank
to side burner
Plug unused hole
with supplied plug.
Side View
back of
box
top of
box
GAS INSTRUCTIONS